{"title":"Heating Season Best Sellers","description":"\u003cp\u003eThe thermostats, gas valves, aquastats and zone valves our customers order most when the heat comes on. In-stock items ship in 1–2 business days.\u003c\/p\u003e","products":[{"product_id":"high-or-low-limit-aquastat-controller-with-100-f-to-240-f-operating-temperature","title":"Resideo L4008A1015\/U High or Low Limit Aquastat Controller with 100 F to 240 F Operating Temperature","description":"\u003cp\u003eThe L4008A1015 is a control from Resideo (Honeywell Home) that senses boiler water temperature and switches the burner, the circulator, or both. It operates over a 100–240 °F range.\u003c\/p\u003e\u003cp\u003eThe aquastat is the control that keeps a hydronic boiler inside its working band. It holds the water hot enough to serve a call for heat and shuts the burner down before the boiler reaches a temperature the relief valve would have to handle.\u003c\/p\u003e\u003cp\u003eWhen you replace an aquastat, match the temperature range, the switch action and the differential to the control coming out, not to the boiler nameplate. A boiler will happily run on a control with the wrong range — it will simply cycle badly, or trip a limit that was never meant to be the working control.\u003c\/p\u003e\u003cp\u003eThe sensing bulb belongs in an immersion well, filled with heat conductive compound, threaded into the tapping the boiler manufacturer provided for it. A bulb strapped to the outside of a pipe reads the pipe, not the water, and it reads it late.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e L4008A1015\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature range:\u003c\/strong\u003e 100–240 °F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Aquastats \u0026amp; Wells\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eHigh or Low Limit Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eHot Water, Hydronic Heating Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003e5 1\/2 ft (1.7 m) Capillary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e100 °F, 38 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e240 °F, 116 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapillary Length\u003c\/th\u003e\n\u003ctd\u003e66 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e5.63 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e2.13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazmat Information\u003c\/th\u003e\n\u003ctd\u003eDangerous Goods in Excepted Quantities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/60-0912.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for L4008E Remote Bulb Aquastat Controller (English)\u003c\/a\u003e (1.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95-5971.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for L4008A,B,E,L; L6008A,G,H Aquastat® Controllers (English)\u003c\/a\u003e (0.8MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/60-2104.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for L4006, L4007, L4008, L6006, L6007, L6008 Aquastat Controllers (English)\u003c\/a\u003e (1.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/63-9661.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThe Universal Choice - Selector Guide\/Cross Reference for Residential Combustion Products (English)\u003c\/a\u003e (0.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/67-7518.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCross Reference Guide for Residential Combustion Heating and Cooling Parts (English)\u003c\/a\u003e (2.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/63-9572.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHeating and Cooling Components Application Selection and Cross Reference Guide (English)\u003c\/a\u003e (1.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/63-9575.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResidential Combustion Application Selection and Cross-Reference Guide (English)\u003c\/a\u003e (8.8MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":44351316754535,"sku":"HONE-L4008A1015\/U","price":225.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/L4008A1015-c2-6.jpg?v=1785815789"},{"product_id":"electric-heat-thermostat-hiperf-premier-white-baseboard","title":"Honeywell Home T4398A1021\/U Electric Heat Thermostat HiPerf, Premier White®-Baseboard","description":"\u003cdiv class=\"ths-discontinued\"\u003e\u003cp\u003e\u003cstrong\u003eT4398A1021 has been discontinued by the manufacturer (2026-03).\u003c\/strong\u003e Suggested replacement: \u003ca href=\"\/products\/line-volt-manual-thermostat-with-triac-for-electric-heat\"\u003eTH401 - Digital Non-Programmable Line Volt Thermostat for Electric Heating (120\/240 VAC, SPST)\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- ths-discontinued --\u003e\n\u003cp\u003eThe T4398A1021 is a non-programmable thermostat from Honeywell Home.\u003c\/p\u003e\u003cp\u003eA non-programmable thermostat holds one setpoint until someone changes it. That is the whole design, and it is the right design more often than the market admits: in a shop, a rental, a spare room or anywhere occupancy has no schedule, a programmable stat gets overridden permanently within a week and then behaves like this one with extra steps.\u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eline-voltage\u003c\/strong\u003e thermostat for electric resistance heat. It carries the heater current itself rather than switching a 24 V control circuit, and it is not interchangeable with a low-voltage stat.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere it hangs decides what it reads.\u003c\/strong\u003e A thermostat measures the air touching it and nothing else, so an interior wall about five feet up, out of direct sun, away from supply registers and doorway drafts, and clear of the back of a wall carrying hot water or flue pipe. Most complaints that a stat is “off by three degrees” are placement, not calibration — the stat is reading the truth about a spot nobody lives in.\u003c\/p\u003e\u003cp\u003eConfirm the system type before ordering — low voltage, line voltage and millivolt thermostats look similar and are not interchangeable.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e T4398A1021\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Non-programmable thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Line voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 0.5 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eReplacement\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer has discontinued this model. Recommended replacements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/electromechanical-heating-relay-with-208-240v-transformer\"\u003eElectromechanical Heating Relay with 208\/240V Transformer (RC840T-240\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th109proplus-u-non-programmable-line-voltage-thermostat-3000-w\"\u003eLine Volt Manual TRIAC Electric Heat Thermostat (TH109PROPLUS\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th114-af-024t-u-low-voltage-non-programmable-thermostat-with-floor-sensor-24-v-0-5-a\"\u003eElectric Heating (Ambient and Floor) Manual Thermostat (TH114-AF-024T\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th140-28-01-b-u-7-day-programmable-thermostat-1-heat-spdt-24-120-240-v\"\u003eLine and Low Volt 7-Day Programmable Thermostat Electric Heat (TH140-28-01-B\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eElectric Baseboards, Convectors and Fan-forced Heaters (Resistive Rated Loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eNon programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA Listed: File No. LR1322, UL Listed; File No. E4436, Guide No. XAPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003e1 Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmart Home Integration\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eThermometer, Range stops and locking cover screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ-Wave\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRedLINK\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003ePremier White®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e2 °F, 1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDemand Response\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd\u003e1 °C, 2 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eVertical Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.5 in, 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e2.88 in, 73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e2.63 in, 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHazmat Information\u003c\/th\u003e\n\u003ctd\u003eUN 2037, RECEPTACLES, SMALL, CONTAINING GAS, 2.1 - Limited Quantity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10004\/95C-10708.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 272804A with T410, T4398, and T4098 Thermostats (English)\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10004\/69-1604.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct data for T4398 Precision Electric Heating Thermostat (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351324979303,"sku":"HONE-T4398A1021\/U","price":36.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/CT62B1015-c1-6.jpg?v=1785815962"},{"product_id":"brush-gold-baseboard-electric-heat-thermostat","title":"Resideo T498B1512\/U Brush Gold Baseboard Electric Heat Thermostat","description":"\u003cdiv class=\"ths-discontinued\"\u003e\u003cp\u003e\u003cstrong\u003eT498B1512 has been discontinued by the manufacturer (2026-04).\u003c\/strong\u003e Suggested replacement: \u003ca href=\"\/products\/line-volt-manual-thermostat-for-electric-heat\"\u003eTH114-A-240D-B - Non-Programmable Line Volt Thermostat for Electric Heating (DPST)\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- ths-discontinued --\u003e\n\u003cp\u003eThe T498B1512 is a line-voltage thermostat from Resideo (Honeywell Home) for electric resistance heat — baseboard, convectors, radiant ceiling or panel heaters.\u003c\/p\u003e\u003cp\u003eLine voltage is the distinction that matters here. A low-voltage thermostat switches a 24 V control circuit and lets a furnace or boiler do the work; a line-voltage thermostat carries the full heater current itself. They are not interchangeable, and a low-voltage stat wired to a baseboard circuit fails immediately.\u003c\/p\u003e\u003cp\u003eMatch the voltage and the pole configuration to the heater circuit, and check the amperage of the heater against the rating of the thermostat. A thermostat sized below the load is the most common cause of a line-voltage stat failing in its first season.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e T498B1512\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Line-voltage thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 0.5 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Line Voltage Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eElectric baseboards, Convectors and fan forced heaters (resistive rated loads).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eNon programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA Listed: File No. LR1322, UL Listed; File No. E4436, Guide No. XAPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003e1 Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmart Home Integration\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003eManual \/ Not Programmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003ePositive OFF, Range stops, Locking cover, Extra knob decal for recalibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ-Wave\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRedLINK\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eBimetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e85 °F, 27°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e3 °F, 2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDemand Response\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd\u003e2, 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Connection Type\u003c\/th\u003e\n\u003ctd\u003e6 in Copper Leadwires, 150 mm Copper Leadwires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eSingle Gang Electrical Box, Vertical Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e80 °F, 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitch Action\u003c\/th\u003e\n\u003ctd\u003eDPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003eJ-Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.56 in, 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e2.88 in, 73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.9375 in, 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95C-10685B.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for T498A, B Electric Heating Thermostat (English, French)\u003c\/a\u003e (1.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95C-10686.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for T498A,B Electric Heat Thermostats (English)\u003c\/a\u003e (0.8MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":44351325110375,"sku":"HONE-T498B1512\/U","price":63.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/T498A1810-c1-6_f6db928c-a5db-40c8-88e7-168e05d0e2f7.jpg?v=1785815967"},{"product_id":"pro-2000-horizontal-programmable-thermostat","title":"Honeywell Home PRO 2000 Horizontal Programmable Thermostat TH2110DH1002\/U","description":"\u003cdiv class=\"ths-discontinued\"\u003e\u003cp\u003e\u003cstrong\u003eTH2110DH1002 has been discontinued by the manufacturer (2026-03).\u003c\/strong\u003e Suggested replacement: \u003ca href=\"\/products\/resideo-th2110u4004-u-focuspro-200-programmable-thermostat-1-heat-1-cool\"\u003eTH2110U4004 - FocusPro P200 Programmable, 1H\/1C, Large Display Thermostat\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- ths-discontinued --\u003e\n\u003cp\u003eThe Honeywell Home TH2110DH1002\/U is a PRO 2000 wall thermostat. The case is the \u003cstrong\u003ehorizontal\u003c\/strong\u003e version — horizontal and the other orientation are electrically the same thermostat in a different body, so pick the one that matches the footprint and the wire opening already in the wall. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable.\u003c\/strong\u003e Setback on a schedule is where the savings actually come from on a system that runs daily. If the building empties on a predictable pattern, the schedule pays for the difference in price over a non-programmable unit; if it does not, it will not.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits in the range.\u003c\/strong\u003e Resideo builds these in tiers, and the tier number is the amount of control you get, not the build quality. T1 and PRO 1000 are single-stage and non-programmable — set it and leave it. T3 and PRO 3000 add a digital display and more staging. T4 and PRO 2000 add scheduling. T6 covers multi-stage and heat pump work, with a Smart version that adds Wi-Fi. T10 Pro is the top of the line, with RedLINK and remote room sensing. \u003cstrong\u003ePRO 1000, PRO 2000 and PRO 3000 are the older names for the same tiers\u003c\/strong\u003e as T1, T4 and T3 — if you are matching what came out of the wall, the PRO number and the T number can be the same generation of product under two labels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore you order.\u003c\/strong\u003e Match the thermostat to the equipment, not to the room: count the heating and cooling stages the system actually has, and confirm whether it is a heat pump or a conventional system, because the two wire differently at the thermostat. A unit rated for more stages than you have will work; one rated for fewer will not run the equipment you own. If you are replacing a Honeywell Home unit, the part number carries over — Honeywell Home thermostats are made by Resideo, and the legacy numbering is the same.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003eNon-programmable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/programmable-thermostats\"\u003eProgrammable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/smart-thermostats\"\u003eSmart thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/resideo\"\u003eAll Resideo\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH2110DH1002\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267463171\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eReplacement\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer has discontinued this model. Recommended replacements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th2110u4004-u-focuspro-200-programmable-thermostat-1-heat-1-cool\"\u003eFocusPRO® P200 Programmable Thermostat 1H\/1C Compatibile (TH2110U4004\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th2110wf4008-u-focuspro-wi-fi-smart-thermostat-1h-1c\"\u003eFocusPRO® S200 Smart Thermostat 1H\/1C Compatible (TH2110WF4008\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003e24 V AC systems, gas, oil, electric warm air, hot water coil, electric hydronic, steam\/gravity systems, 750 mV Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eProgrammable, Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003e1 Heat\/1 Cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmart Home Integration\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003eLCD Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e1.73 sq in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Language\u003c\/th\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Time Format\u003c\/th\u003e\n\u003ctd\u003e24 Hour, 12 Hour (AM\/PM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat, Cool, Auto, Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003e5-2 Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eBattery Powered, Hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Type\u003c\/th\u003e\n\u003ctd\u003eAlkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Source\u003c\/th\u003e\n\u003ctd\u003eHardwired, Battery Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Size\u003c\/th\u003e\n\u003ctd\u003eAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eThermostat, Wall Anchors, Screws, Batteries, Literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ-Wave Specifications\u003c\/th\u003e\n\u003ctd\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRedLINK\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003ePremier White®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e102 °F, 39 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e32 °F, 0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e± 1 °F, ± 0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock Type\u003c\/th\u003e\n\u003ctd\u003eWeek Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRunning Current\u003c\/th\u003e\n\u003ctd\u003e0.02 A to 1.0 A running\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Connection Type\u003c\/th\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eHorizontal Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNumber of Fan Speeds\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003eHeat: 90 °F, Heat: 32 °C, Cool: 99 °F, Cool: 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003eHeat: 40 °F, Heat: 4.5 °C, Cool: 50 °F, Cool: 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e3.44 in, 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.19 in, 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/33-00304EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Information for PRO 2000 Series (English, French, Spanish)\u003c\/a\u003e (0.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-2608EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOperating Manual for PRO 2000 Series Programmable Thermostat (English, French, Spanish)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-2609EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Guide for the PRO TH1000E1, TH1000DH, TH2000DH Series Thermostats (English, French, Spanish)\u003c\/a\u003e (2.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/50-9580.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for PRO 1000\/2000 Non-Programmable and Programmable Thermostats (English)\u003c\/a\u003e (1.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-1376.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProgrammable and Non-Programmable Thermostat Selection Guide (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00527.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for Pro 1000 \u0026amp; 2000 Series Thermostats (English)\u003c\/a\u003e (0.1MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351326781543,"sku":"HONE-TH2110DH1002\/U","price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH2110DH1002-c1-6.jpg?v=1785816006"},{"product_id":"t3-pro-non-programmable-thermostat-hone-th3210u2004-u","title":"Honeywell Home T3 Pro Non-Programmable Thermostat TH3210U2004\/U","description":"\u003cdiv class=\"ths-discontinued\"\u003e\u003cp\u003e\u003cstrong\u003eTH3210U2004 has been discontinued by the manufacturer (2025-11).\u003c\/strong\u003e Direct replacement: \u003ca href=\"\/products\/resideo-th1210u4001-u-focuspro-n100-non-programmable-thermostat-2-heat-1-cool\"\u003eTH1210U4001 - FocusPRO N100 Non-Programmable Thermostat (2H\/1C)\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- ths-discontinued --\u003e\n\u003cp\u003eThe Honeywell Home TH3210U2004\/U is a T3 Pro wall thermostat. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNon-programmable.\u003c\/strong\u003e One setpoint, changed by hand. That is the right choice for a rental, a shop, a space on a fixed occupancy, or any job where a schedule would just get overridden. Fewer things to explain at handover, and nothing to reprogram after a power event.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits in the range.\u003c\/strong\u003e Resideo builds these in tiers, and the tier number is the amount of control you get, not the build quality. T1 and PRO 1000 are single-stage and non-programmable — set it and leave it. T3 and PRO 3000 add a digital display and more staging. T4 and PRO 2000 add scheduling. T6 covers multi-stage and heat pump work, with a Smart version that adds Wi-Fi. T10 Pro is the top of the line, with RedLINK and remote room sensing. \u003cstrong\u003ePRO 1000, PRO 2000 and PRO 3000 are the older names for the same tiers\u003c\/strong\u003e as T1, T4 and T3 — if you are matching what came out of the wall, the PRO number and the T number can be the same generation of product under two labels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore you order.\u003c\/strong\u003e Match the thermostat to the equipment, not to the room: count the heating and cooling stages the system actually has, and confirm whether it is a heat pump or a conventional system, because the two wire differently at the thermostat. A unit rated for more stages than you have will work; one rated for fewer will not run the equipment you own. If you are replacing a Honeywell Home unit, the part number carries over — Honeywell Home thermostats are made by Resideo, and the legacy numbering is the same.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003eNon-programmable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/programmable-thermostats\"\u003eProgrammable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/smart-thermostats\"\u003eSmart thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/resideo\"\u003eAll Resideo\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH3210U2004\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 194159005013\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eReplacement\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer has discontinued this model. Recommended replacements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th1320u4002-u-focuspro-100-non-programmable-thermostat-3-heat-2-cool\"\u003eFocusPRO® N100 Non-Programmable Thermostat 3H\/2CHeatPump+2H\/2C Conventional (TH1320U4002\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th1210u4001-u-focuspro-n100-non-programmable-thermostat-2-heat-1-cool\"\u003eFocusPRO® N100 Non-Programmable Thermostat2H\/1C HeatPump+1H\/1C Conventional (TH1210U4001\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003e2H\/1C heat pump with auxiliary heat or 1H\/1C conventional systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd\u003eReady out of the box, Large, backlit digital display, Intuitive up and down vertical buttons, Precise comfort accuracy of +\/-1°F, UWP for easy upgrades, 5-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003eUp to 2 Heat\/1 Cool Heat Pump Systems, 1 Heat\/1 Cool Conventional Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e3.79 sq in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Language\u003c\/th\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat, Cool, Emergency Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003eManual \/ Not Programmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlerts and Reminders\u003c\/th\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eBattery, Hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Source\u003c\/th\u003e\n\u003ctd\u003eHardwired, Battery Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eThermostat, UWP Wall plate, Cover Plate, Screws and anchors, Literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ-Wave\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRedLINK\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e102 °F, 39 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e37 °F, 2.8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e± 1 °F, ± 0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Relative Humidity (Max)\u003c\/th\u003e\n\u003ctd\u003e90% non\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Relative Humidity (Min)\u003c\/th\u003e\n\u003ctd\u003e5% non\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Connection Type\u003c\/th\u003e\n\u003ctd\u003eUWP Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eUWP Wall Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003eHeat: 90 °F, Heat: 32 °C, Cool: 99 °F, Cool: 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003eHeat: 40 °F, Heat: 4.5 °C, Cool: 50 °F, Cool: 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitch Type\u003c\/th\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e3.86 in, 98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e5.36 in, 136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.08 in, 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00521EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide for T3 Pro Thermostat (English, French, Spanish)\u003c\/a\u003e (1.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00520EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for T3 Pro Thermostat (English, French, Spanish)\u003c\/a\u003e (2.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/03-00545.pdf\" target=\"_blank\" rel=\"noopener\"\u003eContractor Sell Sheet for T3 Pro Non-programmable Thermostat (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/03-00546.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHomeowners Sell Sheet for T3 Pro Non-programmable Thermostat (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/03-00357.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThe Honeywell Home T Series Brochure (English)\u003c\/a\u003e (3.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-1376.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProgrammable and Non-Programmable Thermostat Selection Guide (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00522EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eT3 Pro Series Thermostats Submittal Sheet (English, French)\u003c\/a\u003e (0.1MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/resideo-thp2400a1075-u-t-series-small-square-cover-plate-and-adapter\"\u003eMedium Cover Plate amd J-Box Adaptor for T Series Thermostats (THP2400A1075\/U)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351326945383,"sku":"HONE-TH3210U2004\/U","price":36.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH3110U2008-c2-6_47a833d7-732f-4ca4-a97f-d30fade4d09a.jpg?v=1785816010"},{"product_id":"focuspro-5000-heating-and-cooling-thermostat-large-display","title":"Honeywell Home TH5110D1022\/U FocusPRO 5000 Heating and Cooling Thermostat Large Display","description":"\u003cdiv class=\"ths-discontinued\"\u003e\u003cp\u003e\u003cstrong\u003eTH5110D1022 has been discontinued by the manufacturer (2026-06).\u003c\/strong\u003e Suggested replacement: \u003ca href=\"\/products\/resideo-th2320u4006-u-focuspro-200-programmable-thermostat-3-heat-2-cool\"\u003eTH2320U4006 - FocusPro P200 Programmable, 3H\/2C Heat Pump, 2H\/2C Conventional, Large Display Thermostat\u003c\/a\u003e.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- ths-discontinued --\u003e\n\u003cp\u003eThe TH5110D1022 is a non-programmable thermostat from Honeywell Home.\u003c\/p\u003e\u003cp\u003eA non-programmable thermostat holds one setpoint until someone changes it. That is the whole design, and it is the right design more often than the market admits: in a shop, a rental, a spare room or anywhere occupancy has no schedule, a programmable stat gets overridden permanently within a week and then behaves like this one with extra steps.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere it hangs decides what it reads.\u003c\/strong\u003e A thermostat measures the air touching it and nothing else, so an interior wall about five feet up, out of direct sun, away from supply registers and doorway drafts, and clear of the back of a wall carrying hot water or flue pipe. Most complaints that a stat is “off by three degrees” are placement, not calibration — the stat is reading the truth about a spot nobody lives in.\u003c\/p\u003e\u003cp\u003eThese are also the straightforward answer to the C-wire problem. A smart thermostat needs a common wire to power itself continuously, and in an older house that wire is often not in the bundle — which turns a thermostat swap into a wire pull. A non-programmable stat does not draw a continuous 24 V supply for itself, so the wires already on the wall are usually the wires it needs.\u003c\/p\u003e\u003cp\u003eIf the stat has an adjustable heat anticipator, set it to the current stamped on the primary control rather than leaving it where it arrived. Too low and the burner shuts off early and the room never reaches setpoint; too high and it overshoots and then coasts cold. It is the one adjustment on a stat like this that changes comfort, and the one most often skipped.\u003c\/p\u003e\u003cp\u003eConfirm the system type before ordering — low voltage, line voltage and millivolt thermostats look similar and are not interchangeable.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH5110D1022\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Non-programmable thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weight:\u003c\/strong\u003e 0.8 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eReplacement\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer has discontinued this model. Recommended replacements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th2110wf4008-u-focuspro-wi-fi-smart-thermostat-1h-1c\"\u003eFocusPRO® S200 Smart Thermostat 1H\/1C Compatible (TH2110WF4008\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th1110u4000-u-focuspro-100-non-programmable-thermostat-1-heat-1-cool\"\u003eFocusPRO® N100 Non-Programmable Thermostat 1H\/1C Compatibility (TH1110U4000\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-th2320u4006-u-focuspro-200-programmable-thermostat-3-heat-2-cool\"\u003eFocusPRO® P200 Programmable Thermostat 3H\/2C Heat Pump + 2H\/2C Conventional (TH2320U4006\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003e1 Heat\/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd\u003ePre-programmed schedule; battery-free; Early Start function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003e1 Heat\/1 Cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e2.98 sq in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Language\u003c\/th\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed Information\u003c\/th\u003e\n\u003ctd\u003eIndoor Temperature, Status Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat, Cool, Auto, Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003eManual \/ Not Programmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlerts and Reminders\u003c\/th\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eBattery, Hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Source\u003c\/th\u003e\n\u003ctd\u003eHardwired, Battery Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eThermostat, Wall anchors, Screws, Literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003ePremier White®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e120 °F, 49 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e32 °F, 0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e1 °F, 0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Connection Type\u003c\/th\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eHorizontal Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNumber of Fan Speeds\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003eHeating: 90 °F, Cooling: 99 °F, Heating: 32 °C, Cooling: 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003eHeating: 40 °F, Cooling: 50 °F, Heating: 4.5 °C, Cooling: 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitch Type\u003c\/th\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e3.44 in, 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.5 in, 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.31 in, 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/69-1713.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTH5110D Non-Programmable Thermostat Operating Instructions (English)\u003c\/a\u003e (1.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/69-1922EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Guide for TH5220, TH5110, TH5000 Series FocusPRO Non-Programmable Digital Thermostat (English, French, Spanish)\u003c\/a\u003e (2.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-1376.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProgrammable and Non-Programmable Thermostat Selection Guide (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9250.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFocusPRO 5000 Digital Non-Programmable Thermostat (English)\u003c\/a\u003e (1.4MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351327076455,"sku":"HONE-TH5110D1022\/U","price":92.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH5110LS-c4-6.jpg?v=1785816012"},{"product_id":"t6-pro-hydronic-programmable-thermostat","title":"Honeywell Home TH6100AF2004\/U T6 Pro Hydronic Programmable Thermostat","description":"\u003cp\u003eThe Honeywell Home TH6100AF2004\/U is a T6 Pro Hydronic wall thermostat. It is rated for hydronic. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable.\u003c\/strong\u003e Setback on a schedule is where the savings actually come from on a system that runs daily. If the building empties on a predictable pattern, the schedule pays for the difference in price over a non-programmable unit; if it does not, it will not.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits in the range.\u003c\/strong\u003e Resideo builds these in tiers, and the tier number is the amount of control you get, not the build quality. T1 and PRO 1000 are single-stage and non-programmable — set it and leave it. T3 and PRO 3000 add a digital display and more staging. T4 and PRO 2000 add scheduling. T6 covers multi-stage and heat pump work, with a Smart version that adds Wi-Fi. T10 Pro is the top of the line, with RedLINK and remote room sensing. \u003cstrong\u003ePRO 1000, PRO 2000 and PRO 3000 are the older names for the same tiers\u003c\/strong\u003e as T1, T4 and T3 — if you are matching what came out of the wall, the PRO number and the T number can be the same generation of product under two labels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore you order.\u003c\/strong\u003e Match the thermostat to the equipment, not to the room: count the heating and cooling stages the system actually has, and confirm whether it is a heat pump or a conventional system, because the two wire differently at the thermostat. A unit rated for more stages than you have will work; one rated for fewer will not run the equipment you own. If you are replacing a Honeywell Home unit, the part number carries over — Honeywell Home thermostats are made by Resideo, and the legacy numbering is the same.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003eNon-programmable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/programmable-thermostats\"\u003eProgrammable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/smart-thermostats\"\u003eSmart thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/resideo\"\u003eAll Resideo\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH6100AF2004\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267735735\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.811 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eProgrammable; Digital; Low Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eThermostat; UWP Mounting System; Honeywell Home Standard Installation Adapter (J-box adapter); Decorative Cover Plate; Screws and anchors; 2 AA Batteries; Installation Instructions and User Guide; AQ12C20 floor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003e1 Heat only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat; Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgramming Features\u003c\/th\u003e\n\u003ctd\u003eFrost Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003eManual \/ Not Programmed; 7-Day Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlerts and Reminders\u003c\/th\u003e\n\u003ctd\u003eBattery Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003eLCD Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplayed Information\u003c\/th\u003e\n\u003ctd\u003eIndoor Temperature; Mode; Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeatures\u003c\/th\u003e\n\u003ctd\u003eBacklit Display ; Smart Response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Type\u003c\/th\u003e\n\u003ctd\u003eAlkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.06 in; 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.06 in; 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.09 in; 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00343EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide for T6 Pro Hydronic Programmable Thermostat\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/03-00357.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThe Honeywell Home T Series Brochure\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351327141991,"sku":"HONE-TH6100AF2004\/U","price":138.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH6100AF2004-c3-6.jpg?v=1785816013"},{"product_id":"t6-pro-programmable-thermostat-up-to-2-heat-2-cool","title":"Honeywell Home TH6220U2000\/U T6 Pro Programmable Thermostat up to 2 Heat\/2 Cool","description":"\u003cp\u003eThe Honeywell Home TH6220U2000\/U is a T6 Pro wall thermostat. It is rated for up to 2 heat and 2 cool. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable.\u003c\/strong\u003e Setback on a schedule is where the savings actually come from on a system that runs daily. If the building empties on a predictable pattern, the schedule pays for the difference in price over a non-programmable unit; if it does not, it will not.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits in the range.\u003c\/strong\u003e Resideo builds these in tiers, and the tier number is the amount of control you get, not the build quality. T1 and PRO 1000 are single-stage and non-programmable — set it and leave it. T3 and PRO 3000 add a digital display and more staging. T4 and PRO 2000 add scheduling. T6 covers multi-stage and heat pump work, with a Smart version that adds Wi-Fi. T10 Pro is the top of the line, with RedLINK and remote room sensing. \u003cstrong\u003ePRO 1000, PRO 2000 and PRO 3000 are the older names for the same tiers\u003c\/strong\u003e as T1, T4 and T3 — if you are matching what came out of the wall, the PRO number and the T number can be the same generation of product under two labels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore you order.\u003c\/strong\u003e Match the thermostat to the equipment, not to the room: count the heating and cooling stages the system actually has, and confirm whether it is a heat pump or a conventional system, because the two wire differently at the thermostat. A unit rated for more stages than you have will work; one rated for fewer will not run the equipment you own. If you are replacing a Honeywell Home unit, the part number carries over — Honeywell Home thermostats are made by Resideo, and the legacy numbering is the same.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003eNon-programmable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/programmable-thermostats\"\u003eProgrammable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/smart-thermostats\"\u003eSmart thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/resideo\"\u003eAll Resideo\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH6220U2000\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267569507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 0.811 lb\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eProgrammable; Digital; Low Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eT6 Pro Thermostat; UWP Wall Plate; Decorative Cover Plate; Screws and anchors; 2 AA Batteries; Literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003eUp to 2 Heat\/1 Cool Heat Pump Systems; 1 Heat\/1 Cool Conventional Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat; Cool; Emergency Heat; Off; Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003e5-2 Programmable; 7-Day Programmable; 5-1-1 Programmable; Scheduled Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFan Function\u003c\/th\u003e\n\u003ctd\u003eCycled; Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlerts and Reminders\u003c\/th\u003e\n\u003ctd\u003eHigh Indoor Temperature; Low Indoor Temperature; Heat Pump Error; Battery Replacement; WiFi No Internet; Filter Change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003eLCD Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeatures\u003c\/th\u003e\n\u003ctd\u003eAdaptive Intelligent Recovery; Backlit Display ; Filter Change Reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Source\u003c\/th\u003e\n\u003ctd\u003eHardwired; Battery Operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBattery Type\u003c\/th\u003e\n\u003ctd\u003eAlkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.06 in; 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.06 in; 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.09 in; 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/33-00181EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for T6 Pro Programmable Thermostat\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00182EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide for T6 Pro (TH6320U, TH6220U, TH6210U) Programmable Thermostat\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/33-00279EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for T Series Thermostat Guard TG511A\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00537EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide for T6 Pro Programmable Thermostat\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-1376.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProgrammable and Non-Programmable Thermostat Selection Guide\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10006\/33-00669EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstaller Guide for T6 Pro Programmable Thermostat\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351327273063,"sku":"HONE-TH6220U2000\/U","price":123.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH6210U2001_TH6220U2000_TH6320U2008-c4-6_ad8f6e01-de71-495f-9da2-7f8a27cadbaf.jpg?v=1785816018"},{"product_id":"t6-pro-smart-thermostat-multi-stage-2-heat-2-cool","title":"Honeywell Home TH6220WF2006\/U T6 Pro Smart Thermostat Multi-Stage 2 Heat\/2 Cool","description":"\u003cp\u003eThe Resideo TH6220WF2006\/U is a T6 Pro Smart smart Wi-Fi wall thermostat. It is rated for multi-stage, up to 2 heat and 2 cool. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmart and connected.\u003c\/strong\u003e Wi-Fi gives remote setpoint control and alerting from a phone, which matters most on a property you do not stand in every day — a rental, a second home, a small commercial space. It also means the thermostat needs a reliable common wire and a network that stays up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere it sits in the range.\u003c\/strong\u003e Resideo builds these in tiers, and the tier number is the amount of control you get, not the build quality. T1 and PRO 1000 are single-stage and non-programmable — set it and leave it. T3 and PRO 3000 add a digital display and more staging. T4 and PRO 2000 add scheduling. T6 covers multi-stage and heat pump work, with a Smart version that adds Wi-Fi. T10 Pro is the top of the line, with RedLINK and remote room sensing. \u003cstrong\u003ePRO 1000, PRO 2000 and PRO 3000 are the older names for the same tiers\u003c\/strong\u003e as T1, T4 and T3 — if you are matching what came out of the wall, the PRO number and the T number can be the same generation of product under two labels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore you order.\u003c\/strong\u003e Match the thermostat to the equipment, not to the room: count the heating and cooling stages the system actually has, and confirm whether it is a heat pump or a conventional system, because the two wire differently at the thermostat. A unit rated for more stages than you have will work; one rated for fewer will not run the equipment you own. If you are replacing a Honeywell Home unit, the part number carries over — Honeywell Home thermostats are made by Resideo, and the legacy numbering is the same.\u003c\/p\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003eNon-programmable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/programmable-thermostats\"\u003eProgrammable thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/smart-thermostats\"\u003eSmart thermostats\u003c\/a\u003e · \u003ca href=\"\/collections\/resideo\"\u003eAll Resideo\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH6220WF2006\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267183925\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003e24 Vac systems; Gas, Oil, Electric Warm Air, Hot water Coil; Gas, Oil, Electric Hydronic, Steam \/ Gravity Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd\u003eTH6320WF2003 Up to 3H\/2C heat pump and 2H\/2C conventional, TH6220WF2006 Up to 2H\/1C heat pump and 2H\/2C conventional, Geofencing, 7-day, 5-2, 5-1-1, 1-week or non-programmable, Optional ventilation control for projects that need to meet the ASHRAE 62.2 standard (TH6320WF only), Optional dual fuel (TH6320WF only), Uses the UWP mounting system that’s standard across all T Series thermostats, Setup and scheduling can be done at the wall on the thermostat, or using the Lyric app., Simple homeowner hand-off process enables customers to complete the WiFi connection process on their own, Integrates with smart home Apple HomeKit and Amazon Alexa for customers who want to control their smart home devices from a single app, Customers can program a schedule or use location-based control with geofence technology, which uses their smartphone location to save energy when they’re away and make the home comfortable when they return, Optional wired indoor\/outdoor sensors, Large touchscreen display, 5-year warranty, ENERGY STA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermostat Type\u003c\/th\u003e\n\u003ctd\u003eProgrammable, Digital, Low Voltage, WiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003eUp to 2 Heat\/1 Cool Heat Pump Systems, Up to 2 Heat\/2 Cool Conventional Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmart Home Integration\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003eTouch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e6.89 sq in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTouchscreen\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Time Format\u003c\/th\u003e\n\u003ctd\u003e24 Hour, 12 Hour (AM\/PM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModes of Operation\u003c\/th\u003e\n\u003ctd\u003eHeat, Cool, Emergency Heat, Off, Auto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgramming Features\u003c\/th\u003e\n\u003ctd\u003eGeofencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProgram Type\u003c\/th\u003e\n\u003ctd\u003e5-1-1 Programmable, 5-2 Programmable, 7-Day Programmable, Manual \/ Not Programmed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnergy Star Certified\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlerts and Reminders\u003c\/th\u003e\n\u003ctd\u003eHigh Indoor Temperature, Low Indoor Temperature, Heat Pump Error, AC Power Resumed, Vent Core, Vent Filter, UV Bulb 1, UV Bulb 2, Filter Change 1, Filter Change 2, Humidifier Pad (through app), Humidifier Clean Tank, WiFi No Internet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eHardwired, Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eT6 PRO WiFi Thermostat, UWP Mounting System, Decorative Cover Plate, Screws and anchors, Thermostat Literature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCommunication Type\u003c\/th\u003e\n\u003ctd\u003eWiFi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiFi Specifications\u003c\/th\u003e\n\u003ctd\u003e802.11b, 802.11g, 802.11n, 2.4GHz range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eZ-Wave Specifications\u003c\/th\u003e\n\u003ctd\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRedLINK\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e102 °F, 39 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e37 °F, 2.8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential Temperature\u003c\/th\u003e\n\u003ctd\u003e± 1 °F, ± 0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Relative Humidity (Max)\u003c\/th\u003e\n\u003ctd\u003e90% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Relative Humidity (Min)\u003c\/th\u003e\n\u003ctd\u003e5% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBacklight Options\u003c\/th\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFan Function\u003c\/th\u003e\n\u003ctd\u003eCycled, Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClock Type\u003c\/th\u003e\n\u003ctd\u003eYear Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDemand Response\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRunning Current\u003c\/th\u003e\n\u003ctd\u003e0.02 A to 1.0 A running\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.5 °C, ±1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical Connection Type\u003c\/th\u003e\n\u003ctd\u003eUWP Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterstage Differential Temperature\u003c\/th\u003e\n\u003ctd\u003e1 to 1.5 °F Multistage only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003eUWP Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003eHeat: 90 °F, Heat: 32 °C, Cool: 99 °F, Cool: 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSet point Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003eHeat: 40 °F, Heat: 4.5 °C, Cool: 50 °F, Cool 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Location\u003c\/th\u003e\n\u003ctd\u003eWall, Internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSwitch Type\u003c\/th\u003e\n\u003ctd\u003eRelay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible App\u003c\/th\u003e\n\u003ctd\u003eFirst Alert App, Resideo App\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.06 in, 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.06 in, 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Depth\u003c\/th\u003e\n\u003ctd\u003e1.09 in, 28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFeatures\u003c\/th\u003e\n\u003ctd\u003eENERGY STAR Certified, High Definition Video, Touchscreen Display, Utility Rewards, WiFi, Smart Response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10004\/33-00391EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGetting Started Guide for T6 Pro Wi-Fi Programmable Thermostat (English, French, Spanish)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10018\/33-00392EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Install Guide - T6 Pro Smart Programmable Thermostat (English, French, Spanish)\u003c\/a\u003e (7.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/33-00410EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser Guide for T6 Pro WiFi Programmable Thermostat (English, French, Spanish)\u003c\/a\u003e (28.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10004\/33-00324.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAddendum for T6 PRO Wiring Diagrams (English)\u003c\/a\u003e (1.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10004\/33-00397.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAddendum for Honeywell Easy Ventilation Wiring (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/03-00306.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThe Honeywell Home T Series (tri-fold) Brochure (English)\u003c\/a\u003e (8.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/03-00308.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for T6 Pro Smart Thermostats (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/03-00307.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntroducing The New Standard for Simple (T Series) Sell Sheet (English)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-tg512a1009-u-large-clear-universal-thermostat-guard\"\u003eClear Large Thermostat Guard (TG512A1009\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-32321051-001-u-uwp-16-pin-subbase-for-uwp-based-thermostats\"\u003eUWP mounting system for T Series thermostats (32321051-001\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-thp2400a1075-u-t-series-small-square-cover-plate-and-adapter\"\u003eMedium Cover Plate amd J-Box Adaptor for T Series Thermostats (THP2400A1075\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/c7089u1006-remote-outdoor-temperature-sensor\"\u003eC7089U1006 Remote Outdoor Temperature Sensor (C7089U1006\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351327305831,"sku":"HONE-TH6220WF2006\/U","price":190.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH6220WF2006-c3-6.jpg?v=1785816020"},{"product_id":"24-vac-3-4-in-sweat-n-c-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1012\/U Zone Valve, 24 VAC, 3\/4 in Sweat, Normally Closed, 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1012 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043E1012 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1012\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329828967,"sku":"HONE-V8043E1012\/U","price":138.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E-c41-6.jpg?v=1785816087"},{"product_id":"two-stage-gas-controls-for-direct-ignition-appliance-1-2-in-x-1-2-in-inlet-outlet-size-standard-opening-24-v-ac-natural-gas","title":"Resideo VR8205Q2795T\/U Two Stage Gas Controls for Direct Ignition Appliance, 1\/2 in x 1\/2 in Inlet\/Outlet Size, Standard Opening, 24 V AC, Natural Gas","description":"\u003cp\u003eThe VR8205Q2795T is a two-stage gas control valve from Resideo (Honeywell Home) for direct ignition appliances, 1\/2 in x 1\/2 in inlet and outlet, 24 Vac coil.\u003c\/p\u003e\u003cp\u003eThe gas valve is the component that admits fuel to the burner and shuts it off. It carries the main shutoff, the pressure regulator that holds manifold pressure steady as supply pressure varies, and the safety interlock that keeps gas off until the control system has proved it is safe to light.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDirect ignition\u003c\/strong\u003e skips the pilot entirely: the main burner is lit directly by a spark or a hot surface igniter and proved by flame rectification. Fewer parts in the gas path, and nothing burning between cycles.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003estandard opening\u003c\/strong\u003e. A slow-opening valve ramps the burner up over a couple of seconds to soften the light-off; a standard-opening valve goes to full rate at once. Match the opening rate of the valve coming out — this is one of the differences that does not show on the outside of the body.\u003c\/p\u003e\u003cp\u003eTwo-stage firing lets the appliance run at part load for most of the season and only go to full rate when the load demands it. Longer, gentler burns hold temperature more evenly and cut the cycling losses that come with a single-stage burner switching hard on and off.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGas appliance safety.\u003c\/strong\u003e A gas valve must match the appliance it is fitted to — ignition system, capacity, inlet pressure and gas type. Replacement is work for a licensed gas technician, and the appliance manufacturer's parts list is what decides the correct valve, not the physical fit of the threads. If the replacement does not match, the appliance can fail to light, fail to prove flame, or overfire.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e VR8205Q2795T\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas control valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition system:\u003c\/strong\u003e Direct ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStaging:\u003c\/strong\u003e Two-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil voltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet x outlet:\u003c\/strong\u003e 1\/2 in x 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpening rate:\u003c\/strong\u003e Standard opening\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267665131\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Gas Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eTwo-Stage Standard Opening Valve for Direct Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition Type\u003c\/th\u003e\n\u003ctd\u003eDirect Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of Fuel\u003c\/th\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity (Min)\u003c\/th\u003e\n\u003ctd\u003e20,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet Connection Size\u003c\/th\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet Connection Size\u003c\/th\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRegulation Type\u003c\/th\u003e\n\u003ctd\u003eStandard Two Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eS89C, S89E, S89F, S87 Series 5 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd\u003eON-OFF Lighting Sequence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eStraight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e175 °F, 79 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e-40 °F, -40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Component Recognized MH5323, CSA International: 112395, Australian Gas Association design certificate: 4214, Approved for Delta C Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBlack, Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd\u003e0° to 90° in any direction from the upright position of the gas control knob, including vertically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 117 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e0.34 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.13 in, 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/69-0329.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8205, VR8205 Direct Ignition Combination Gas Controls (English)\u003c\/a\u003e (0.8MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0373.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGas Valve Lighting Instructions for V4204, V4205, V8204, V8205, VR4204, VR8204, VR4205, VR8205, SV9501, SV9502, SV9601, or SV9602 Gas Controls (English)\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-0049.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for VR4205, VR8205 Direct Ignition Dual Automatic Valve Combination Gas Controls (English)\u003c\/a\u003e (1.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/67-7518.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCross Reference Guide for Residential Combustion Heating and Cooling Parts (English)\u003c\/a\u003e (2.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/63-9572.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHeating and Cooling Components Application Selection and Cross Reference Guide (English)\u003c\/a\u003e (1.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/63-9575.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResidential Combustion Application Selection and Cross-Reference Guide (English)\u003c\/a\u003e (8.8MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-393690-13-u-1-2-in-angle-flange-with-hex-screws-and-9-64-in-hex-wrench\"\u003eFlange Kit Bag Assembly - 1\/2 in NPT Elbow Flange (393690-13\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-393690-15-u-3-4-in-angle-flange-with-hex-screws-and-9-64-in-hex-wrench\"\u003eFlange Kit Bag Assembly - 3\/4 in NPT Elbow Flange (393690-15\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-393690-4-u-3-4-in-straight-flange-with-hex-screws-and-dust-plug\"\u003eFlange Kit Bag Assembly - 3\/4 in NPT Straight Flange (393690-4\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/two-stage-natural-to-lp-gas-conversion-kit-8-in-wc-to-11-in-wc-adjustment-range\"\u003eConversion Kit -Natural to LP Gas, 8 in WC to 11 in WC adjustment range (396021\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/two-stage-lp-to-natural-gas-conversion-kit-3-in-wc-to-5-in-wc-adjustment-range\"\u003e396025 Conversion Kit -LP to Natural Gas, 3 in WC to 5 in WC adjust range (396025\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/resideo-390427e-u-3-4-in-npt-x-1-2-in-npt-reducer-bushing-pack-of-2\"\u003eTwo 3\/4 in X 1\/2 in Reducer Bushings (390427E\/U)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":44351333630055,"sku":"HONE-VR8205Q2795T\/U","price":211.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/VR8205Q-c2-6_b9194d1c-27e0-40e4-99b7-bf42fc1f7bff.jpg?v=1785816154"},{"product_id":"resideo-th3110d1008-u-pro-3000-non-programmable-digital-thermostat-1-heat-1-cool","title":"Resideo TH3110D1008\/U PRO 3000 Non-Programmable Digital Thermostat, 1 Heat\/1 Cool","description":"\u003cp\u003eResideo TH3110D1008\/U is a Honeywell Home PRO 3000 non-programmable digital thermostat for 1 heat\/1 cool systems, made for basic operation and simple temperature control.\u003c\/p\u003e\u003cp\u003eIt has a backlit digital display that shows both the current and the set temperature, and a fan On\/Auto setting. The thermostat is low voltage and comes with the UWP Mounting System, a Honeywell Home standard installation adapter (J-box adapter), screws and anchors, and installation instructions and user guide. It measures 3-13\/16 in. high x 5-3\/8 in. wide x 1-1\/4 in. deep and has a 5-year warranty with normal use.\u003c\/p\u003e\u003cp\u003eBefore ordering, confirm the system is a 1H\/1C conventional system or a single-stage heat pump with no auxiliary heat, which is the listed application. Resideo intends it for professional installation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e TH3110D1008\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PRO 3000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Premier White\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat Type:\u003c\/strong\u003e Non-programmable, Digital, Low Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e 1H\/1C Conventional; Single Stage Heat Pump with No Auxiliary Heat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Function:\u003c\/strong\u003e On, Auto\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3-13\/16 in. H x 5-3\/8 in. W x 1-1\/4 in. D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e Thermostat; UWP Mounting System; J-box adapter; Screws and anchors; Installation Instructions and User Guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267265140\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Non-Programmable Thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/dzhpkjoqj\/Resideo\/03-00522.pdf\" target=\"_blank\" rel=\"noopener\"\u003eContractor Sell Sheet for Pro 3000 Non-programmable Thermostat (English)\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/dzhpkjoqj\/Resideo\/03-00522F.pdf\" target=\"_blank\" rel=\"noopener\"\u003eContractor Sell Sheet for Pro 3000 Non-programmable Thermostat (French)\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/dzhpkjoqj\/Resideo\/69-1929EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for PRO TH3000 Series Non-Programmable Digital Thermostat (English, French, Spanish)\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/res.cloudinary.com\/dzhpkjoqj\/Resideo\/33-00300EFS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Information for PRO 3000 Series Digital Thermostat (English, French, Spanish)\u003c\/a\u003e (PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSee also: \u003ca href=\"\/collections\/non-programmable-thermostats\"\u003enon-programmable thermostats\u003c\/a\u003e.\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":50497084325991,"sku":"HONE-TH3110D1008\/U","price":30.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/TH3110D1008-c2-6.jpg?v=1792303204"}],"url":"https:\/\/www.thehousesupplier.com\/collections\/heating-season-best-sellers.oembed","provider":"The House Supplier","version":"1.0","type":"link"}