{"title":"Honeywell Zone Valves","description":"\u003cp\u003eHoneywell Home zone valves and their replacement parts. The range covers V8043 2-way valves at 24 VAC, V4043 2-way valves at 120 VAC, V8044 and V4044 3-way diverting valves, plus replacement powerheads, actuators, motors, adapter kits and VC cartridges.\u003c\/p\u003e\n\u003cp\u003eThe model number tells you most of what you need. V80 models run on 24 VAC and V40 models on line voltage. The 43 is a 2-way valve and the 44 a 3-way diverting valve. The letter after it sets the wiring and position: for example, A is normally closed with lead wires, B and D are normally open, and E, F and G add an end switch that can start the boiler or circulator. The rest of the number covers the connection (sweat, NPT, flare or press), the size and the Cv rating.\u003c\/p\u003e\n\u003cp\u003eA failed valve usually does not need a new body. If the valve still seats, replacing the powerhead or motor restores operation without draining the system. Match the head to the original suffix so the end switch and the normally open or normally closed position stay the same.\u003c\/p\u003e\n\u003cp\u003eReplacement heads for all series are also listed in \u003ca href=\"\/collections\/zone-valve-replacement-heads\"\u003ezone valve replacement heads\u003c\/a\u003e. Zone panels and pump relays are in \u003ca href=\"\/collections\/switching-relays\"\u003eswitching relays\u003c\/a\u003e, and other brands are in \u003ca href=\"\/collections\/zone-valves\"\u003eall zone valves\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"24-vac-50-60-hz-replacement-head-for-v8043a","title":"Honeywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement Head for V8043A","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8043A\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-flare-n-c-zone-valve\"\u003eHoneywell Home V8043A1003\/U 24 Vac 1\/2 in Flare N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-sweat-n-c-zone-valve\"\u003eHoneywell Home V8043A1011\/U 24 Vac 1\/2 in Sweat N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-npt-n-c-zone-valve\"\u003eHoneywell Home V8043A1227\/U 24 Vac 1\/2 in NPT N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-pro-press-zone-valve-with-18-in-lead-wire\"\u003eHoneywell Home V8043A1312\/U 24 Vac 3\/4 in Pro Press Zone Valve with 18 in lead wire\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-quickfit-zone-valve\"\u003eHoneywell Home V8043A5029\/U 24 Vac 3\/4 in Sweat N.C. QuickFit® Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-021\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043A Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043A Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeadwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351299551335,"sku":"HONE-40003916-021\/U","price":100.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6.jpg?v=1785815547"},{"product_id":"replacement-head-for-v4043a-120-v-ac-60-hz","title":"Honeywell Home 40003916-024\/U Replacement Head for V4043A, 120 V AC, 60 Hz","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV4043A\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/120-vac-sweat-n-c-zone-valve\"\u003eHoneywell Home V4043A1010\/U 120 Vac Sweat N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/120-vac-npt-n-c-zone-valve\"\u003eHoneywell Home V4043A1705\/U 120 Vac NPT N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-024\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V4043A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V4034A Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV4043A, Two-Way Valves, Valves with Action of Spring Return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.08A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in, 457 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351299682407,"sku":"HONE-40003916-024\/U","price":110.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_83d7e836-b84d-488e-a3f0-9792cd630fb0.jpg?v=1785815548"},{"product_id":"replacement-head-with-end-switch-for-v8044e-24-v-ac-50-60-hz","title":"Honeywell Home 40003916-026\/U Replacement Head with End Switch for V8044E, 24 V AC, 50\/60 Hz","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8044E\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eThis head includes the \u003cstrong\u003eend switch\u003c\/strong\u003e: a dry contact that closes when the valve reaches full open and starts the boiler or circulator. A valve wired for pump start needs a head with the end switch — fitting one without it leaves the zone opening while the circulator never runs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-zone-valve-hone-v8044e1011-u\"\u003eHoneywell Home 24 Vac 3\/4 in Sweat N.C. Zone Valve V8044E1011\/U\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-026\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8044E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043E Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8044E, Two-Way Valves, Valves with Action of Spring Return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in, 457 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351299715175,"sku":"HONE-40003916-026\/U","price":105.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_2986ce26-c2d6-4799-98d4-dec41ccd4a0c.jpg?v=1785815549"},{"product_id":"replacement-head-for-v8043b-24-v-ac-50-60-hz-normally-open","title":"Honeywell Home 40003916-027\/U Replacement Head for V8043B, 24 V AC, 50\/60 Hz, Normally Open","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8043B\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-sweat-n-o-zone-valve\"\u003eHoneywell Home V8043B1019\/U 24 Vac 1\/2 in Sweat N.O. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-o-zone-valve\"\u003eHoneywell Home V8043B1027\/U 24 Vac 3\/4 in Sweat N.O. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-027\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043B Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043B, Two-Way Valves, Valves with Action of Spring return to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in, 457 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351299747943,"sku":"HONE-40003916-027\/U","price":108.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_c31a9663-3191-4532-89cc-5434bf2fd59b.jpg?v=1785815550"},{"product_id":"replacement-head-for-v8044a-24-v-ac-50-60-hz","title":"Honeywell Home 40003916-046\/U Replacement Head for V8044A, 24 V AC, 50\/60 Hz","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8044A\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-sweat-n-c-quickfit-zone-valve\"\u003eHoneywell Home V8044A1010\/U 24 Vac 1\/2 in Sweat N.C. QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-hone-v8044a1044-u\"\u003eHoneywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve V8044A1044\/U\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-npt-nc-quickfit-zone-valve\"\u003eHoneywell Home V8044A1135\/U 24 Vac 1\/2 in NPT NC QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-npt-n-c-quickfit-zone-valve\"\u003eHoneywell Home V8044A1143\/U 24 Vac 3\/4 in NPT N.C. QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-046\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8044A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8044A Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8044A, Diverting Valves, Valves with Action of Spring Return to close \"\"A\"\" port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in, 457 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351299780711,"sku":"HONE-40003916-046\/U","price":108.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_81be230a-4c40-4abc-a3b8-2290ea6bb87a.jpg?v=1785815551"},{"product_id":"replacement-head-for-v4044a-120-vac-60-hz-with-96-in-leads","title":"Honeywell Home 40003916-047\/U Replacement Head for V4044A, 120 VAC, 60 Hz with 96 in Leads","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV4044A\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/120-vac-1-2-in-flare-diverting-quickfit-zone-valve\"\u003eHoneywell Home V4044A1001\/U 120 Vac 1\/2 in Flare Diverting QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/120-vac-1-2-in-sweat-diverting-quickfit-zone-valve\"\u003eHoneywell Home V4044A1019\/U 120 Vac 1\/2 in Sweat Diverting QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/120-vac-3-4-in-sweat-diverting-quickfit-zone-valve\"\u003eHoneywell Home V4044A1191\/U 120 Vac 3\/4 in Sweat Diverting QuickFit Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-047\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V4044A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V4044A Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV4044A, Diverting Valves, Valves with Action of Spring Return to close \"\"A\"\" port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.08A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e96 in, 2438 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351300304999,"sku":"HONE-40003916-047\/U","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_9b0ecea3-e97d-488a-aaff-fac6456e7e48.jpg?v=1785815551"},{"product_id":"replacement-head-for-v8043f-with-end-switch-24-v-ac-50-60-hz","title":"Honeywell Home 40003916-048\/U Replacement Head for V8043F, with End Switch, 24 V AC, 50\/60 Hz","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8043F\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eThis head includes the \u003cstrong\u003eend switch\u003c\/strong\u003e: a dry contact that closes when the valve reaches full open and starts the boiler or circulator. A valve wired for pump start needs a head with the end switch — fitting one without it leaves the zone opening while the circulator never runs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-in-sweat-n-c-zone-valve\"\u003eHoneywell Home V8043F1051\/U 24 Vac 1 in Sweat N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-zone-valve\"\u003eHoneywell Home 24 Vac 3\/4 in Sweat N.C. Zone Valve V8043F1093\/U\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-hone-v8043f5036-u\"\u003eHoneywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve V8043F5036\/U\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-048\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043F Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043F, Two-Way Valves, Valves with Action of Spring Return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eScrew terminal block on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351300337767,"sku":"HONE-40003916-048\/U","price":115.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_906fb269-b68b-4503-a5e7-f19f4034c78e.jpg?v=1785815552"},{"product_id":"replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz","title":"Honeywell Home 40003916-521\/U Replacement Head for V8043A, 5000 Series, 24 V AC, 50\/60 Hz","description":"\u003cp\u003eReplacement actuator head for Honeywell Home \u003cstrong\u003eV8043A\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-flare-n-c-zone-valve\"\u003eHoneywell Home V8043A1003\/U 24 Vac 1\/2 in Flare N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-sweat-n-c-zone-valve\"\u003eHoneywell Home V8043A1011\/U 24 Vac 1\/2 in Sweat N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-npt-n-c-zone-valve\"\u003eHoneywell Home V8043A1227\/U 24 Vac 1\/2 in NPT N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-pro-press-zone-valve-with-18-in-lead-wire\"\u003eHoneywell Home V8043A1312\/U 24 Vac 3\/4 in Pro Press Zone Valve with 18 in lead wire\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-quickfit-zone-valve\"\u003eHoneywell Home V8043A5029\/U 24 Vac 3\/4 in Sweat N.C. QuickFit® Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-521\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eTwo-way Valves, Valves with Action of Spring Return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in, 457 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads on same side of manual lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351300370535,"sku":"HONE-40003916-521\/U","price":112.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c10-6.jpg?v=1785815554"},{"product_id":"adaptor-kit-for-v4043e-j-v8043j-low-pressure-steam-valves","title":"Honeywell Home 40003918-008\/U Adaptor Kit For V4043E, J; V8043J Low Pressure Steam Valves","description":"\u003cp\u003eAdaptor Kit For V4043E,J; V8043J Low Pressure Steam Valves from Honeywell Home, part number 40003918-008\/U. Honeywell Home carries the Honeywell Home line of residential heating controls, and the V-series and VC-series zone valves this part serves are the reference hydronic controls in North American heating.\u003c\/p\u003e\u003cp\u003eRebuilding a zone valve from parts keeps the body in the piping and the actuator in service. On a heating system that is already charged and balanced, replacing a seal or a cartridge is a far smaller job than cutting a valve out of the line and soldering a new one in.\u003c\/p\u003e\u003cp\u003eMatch the part to the model stamped on your valve before ordering. Zone valve bodies from the same series differ by action and by port arrangement, and the rebuild parts are not interchangeable across them.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003918-008\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003918-007U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003918-007U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351300436071,"sku":"HONE-40003918-008\/U","price":25.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003918-002-c1-6_85f49b80-48ee-4313-b7de-b1ba4b624263.jpg?v=1785815555"},{"product_id":"24-volt-replacement-motor-for-v8043-and-v8044","title":"Honeywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044","description":"\u003cp\u003eReplacement actuator motor for Honeywell Home \u003cstrong\u003eV8043 and V8044\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eValves this part is built for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-flare-n-c-zone-valve\"\u003eHoneywell Home V8043A1003\/U 24 Vac 1\/2 in Flare N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-sweat-n-c-zone-valve\"\u003eHoneywell Home V8043A1011\/U 24 Vac 1\/2 in Sweat N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-1-2-in-npt-n-c-zone-valve\"\u003eHoneywell Home V8043A1227\/U 24 Vac 1\/2 in NPT N.C. Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-pro-press-zone-valve-with-18-in-lead-wire\"\u003eHoneywell Home V8043A1312\/U 24 Vac 3\/4 in Pro Press Zone Valve with 18 in lead wire\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-3-4-in-sweat-n-c-quickfit-zone-valve\"\u003eHoneywell Home V8043A5029\/U 24 Vac 3\/4 in Sweat N.C. QuickFit® Zone Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 802360JA\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043, V8044\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Part for V Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043E Zone Valves, V8043A Zone Valves, V8043F Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV4043, V4044 Fan Coil Valves, V8043, V8044 Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eMotor mounting screw and lead connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/69-0481.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 802360 Replacement Motors (English)\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/33-00449.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4043 or V4044 Line Voltage Valves (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351301058663,"sku":"HONE-802360JA\/U","price":49.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/802360JA-c2-6.jpg?v=1785815574"},{"product_id":"277v-replacement-motor-for-v4043-or-v4044-zone-valves","title":"Honeywell Home 802360QA\/U 277V Replacement Motor for V4043 or V4044 Zone Valves","description":"\u003cp\u003eReplacement actuator motor for Honeywell Home \u003cstrong\u003eV4043 and V4044\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfirm compatibility before ordering.\u003c\/strong\u003e This motor is rated 277 V, which is not the supply voltage of the standard residential zone valve lines. Contact us with the model stamped on your valve and we will confirm the fit.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 802360QA\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V4043, V4044\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 277 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Part for V Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV4043 and V4044 Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV4043, V4044 Fan Coil Valves, V8043, V8044 Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eMotor mounting screw and lead connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e277V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent Draw\u003c\/th\u003e\n\u003ctd\u003e0.037A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/69-0481.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 802360 Replacement Motors (English)\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/33-00449.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4043 or V4044 Line Voltage Valves (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351301091431,"sku":"HONE-802360QA\/U","price":65.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/802360JA-c2-6_e057746a-91a2-40f3-b063-0162d7b115b1.jpg?v=1785815574"},{"product_id":"24v-50-60-hz-replacement-motor-for-v8043j-steam-heating-zone-valves","title":"Honeywell Home 802360UA\/U 24V, 50\/60 Hz Replacement Motor for V8043J Steam\/Heating Zone Valves","description":"\u003cp\u003eReplacement actuator motor for Honeywell Home \u003cstrong\u003eV8043J\u003c\/strong\u003e zone valves. When the motor in the valve fails, this part swaps onto the valve body that is already in the piping — the connections stay soldered or threaded in place and the system does not have to be drained.\u003c\/p\u003e\u003cp\u003eReplacing the head instead of the whole valve is the difference between a fifteen-minute service call and a soldering job on a live heating system. It is the reason the V-series has stayed in the field as long as it has.\u003c\/p\u003e\u003cp\u003eConfirm whether your valve is wired for pump start before ordering. A valve whose end-switch contacts are landed on the boiler needs a replacement head that carries the end switch; this one is specified without it.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 802360UA\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e V8043J\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd switch:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Part for V8043J Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043J Steam and heating zone valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV4043, V4044 Fan Coil Valves, V8043, V8044 Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eMotor mounting screw and lead connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/69-0481.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 802360 Replacement Motors (English)\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/33-00449.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4043 or V4044 Line Voltage Valves (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351301124199,"sku":"HONE-802360UA\/U","price":66.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/802360JA-c2-6_8ae63cfc-1a6a-425e-a202-d7992c273cab.jpg?v=1785815575"},{"product_id":"120-vac-sweat-n-c-zone-valve","title":"Honeywell Home V4043A1010\/U 120 Vac Sweat N.C. Zone Valve","description":"\u003cp\u003eThe V4043A1010 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe sweat connections tie the valve into the supply piping, and the V4043A1010 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v4043a-120-v-ac-60-hz\"\u003eHoneywell Home 40003916-024\/U Replacement Head for V4043A, 120 V AC, 60 Hz\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V4043A1010\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv|3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10006\/68-3102.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4043A, V4043B Line Voltage Valves (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329304679,"sku":"HONE-V4043A1010\/U","price":144.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c49-6.jpg?v=1785816069"},{"product_id":"120-vac-npt-n-c-zone-valve","title":"Honeywell Home V4043A1705\/U 120 Vac NPT N.C. Zone Valve","description":"\u003cp\u003eThe V4043A1705 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe NPT connections tie the valve into the supply piping, and the V4043A1705 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v4043a-120-v-ac-60-hz\"\u003eHoneywell Home 40003916-024\/U Replacement Head for V4043A, 120 V AC, 60 Hz\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V4043A1705\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv|3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10006\/68-3102.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4043A, V4043B Line Voltage Valves (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329337447,"sku":"HONE-V4043A1705\/U","price":164.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c22-6.jpg?v=1785816070"},{"product_id":"120-vac-1-2-in-flare-diverting-quickfit-zone-valve","title":"Honeywell Home V4044A1001\/U 120 Vac 1\/2 in Flare Diverting QuickFit Zone Valve","description":"\u003cp\u003eThe V4044A1001 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch flare valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003ediverting\u003c\/strong\u003e valve. Instead of simply opening and closing one path, it moves flow between two outlets, which is how a single circulator can serve a heating zone and an indirect water heater without a second pump.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch flare connections tie the valve into the supply piping, and the V4044A1001 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v4044a-120-vac-60-hz-with-96-in-leads\"\u003eHoneywell Home 40003916-047\/U Replacement Head for V4044A, 120 VAC, 60 Hz with 96 in leads\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V4044A1001\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Diverting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Flare\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e5.38 in, 136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e1.09 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.69 in, 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eFlare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to port A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e4 Cv|3.4 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/95C-10574ED.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNew Style Powerheads V4044C, V8044C, V8044F (English and Dutch) - Legacy Product Document\u003c\/a\u003e (0.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10214.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThree-way Motorized Valves - Legacy Product Document\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/69-0210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZone Valve Sticky-Back Labels - Legacy Product Document\u003c\/a\u003e (0.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10017\/63-1379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4044A, V4044B 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329370215,"sku":"HONE-V4044A1001\/U","price":157.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8044-c12-6.jpg?v=1785816071"},{"product_id":"120-vac-1-2-in-sweat-diverting-quickfit-zone-valve","title":"Honeywell Home V4044A1019\/U 120 Vac 1\/2 in Sweat Diverting QuickFit Zone Valve","description":"\u003cp\u003eThe V4044A1019 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003ediverting\u003c\/strong\u003e valve. Instead of simply opening and closing one path, it moves flow between two outlets, which is how a single circulator can serve a heating zone and an indirect water heater without a second pump.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch sweat connections tie the valve into the supply piping, and the V4044A1019 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v4044a-120-vac-60-hz-with-96-in-leads\"\u003eHoneywell Home 40003916-047\/U Replacement Head for V4044A, 120 VAC, 60 Hz with 96 in leads\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V4044A1019\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Diverting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e0.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to port A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e4 Cv|3.4 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/95C-10574ED.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNew Style Powerheads V4044C, V8044C, V8044F (English and Dutch) - Legacy Product Document\u003c\/a\u003e (0.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10214.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThree-way Motorized Valves - Legacy Product Document\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/69-0210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZone Valve Sticky-Back Labels - Legacy Product Document\u003c\/a\u003e (0.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10017\/63-1379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4044A, V4044B 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329402983,"sku":"HONE-V4044A1019\/U","price":155.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8044-c8-6.jpg?v=1785816072"},{"product_id":"120-vac-3-4-in-sweat-diverting-quickfit-zone-valve","title":"Honeywell Home V4044A1191\/U 120 Vac 3\/4 in Sweat Diverting QuickFit Zone Valve","description":"\u003cp\u003eThe V4044A1191 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003ediverting\u003c\/strong\u003e valve. Instead of simply opening and closing one path, it moves flow between two outlets, which is how a single circulator can serve a heating zone and an indirect water heater without a second pump.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V4044A1191 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v4044a-120-vac-60-hz-with-96-in-leads\"\u003eHoneywell Home 40003916-047\/U Replacement Head for V4044A, 120 VAC, 60 Hz with 96 in leads\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V4044A1191\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Diverting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e0.95 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e10 psi, 69 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to port A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e7 Cv|6 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/95C-10574ED.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNew Style Powerheads V4044C, V8044C, V8044F (English and Dutch) - Legacy Product Document\u003c\/a\u003e (0.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10214.pdf\" target=\"_blank\" rel=\"noopener\"\u003eThree-way Motorized Valves - Legacy Product Document\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10012\/69-0210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eZone Valve Sticky-Back Labels - Legacy Product Document\u003c\/a\u003e (0.0MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10017\/63-1379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V4044A, V4044B 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329435751,"sku":"HONE-V4044A1191\/U","price":171.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/v8044-c1-6.jpg?v=1785816074"},{"product_id":"24-vac-1-2-in-flare-n-c-zone-valve","title":"Honeywell Home V8043A1003\/U 24 Vac 1\/2 in Flare N.C. Zone Valve","description":"\u003cp\u003eThe V8043A1003 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch flare valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch flare connections tie the valve into the supply piping, and the V8043A1003 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-50-60-hz-replacement-head-for-v8043a\"\u003eHoneywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement head for V8043A\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-521\/U Replacement Head for V8043A, 5000 series, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043A1003\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Flare\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e4.69 in, 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eFlare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329468519,"sku":"HONE-V8043A1003\/U","price":144.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/v8043-c39-6.jpg?v=1785816074"},{"product_id":"24-vac-1-2-in-sweat-n-c-zone-valve","title":"Honeywell Home V8043A1011\/U 24 Vac 1\/2 in Sweat N.C. Zone Valve","description":"\u003cp\u003eThe V8043A1011 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch sweat connections tie the valve into the supply piping, and the V8043A1011 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-50-60-hz-replacement-head-for-v8043a\"\u003eHoneywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement head for V8043A\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-521\/U Replacement Head for V8043A, 5000 series, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043A1011\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329501287,"sku":"HONE-V8043A1011\/U","price":132.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c10-6.jpg?v=1785816075"},{"product_id":"24-vac-1-2-in-npt-n-c-zone-valve","title":"Honeywell Home V8043A1227\/U 24 Vac 1\/2 in NPT N.C. Zone Valve","description":"\u003cp\u003eThe V8043A1227 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch NPT connections tie the valve into the supply piping, and the V8043A1227 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-50-60-hz-replacement-head-for-v8043a\"\u003eHoneywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement head for V8043A\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-521\/U Replacement Head for V8043A, 5000 series, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043A1227\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329534055,"sku":"HONE-V8043A1227\/U","price":135.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c22-6_ed2bdf71-d1f7-4d64-b3a1-172c0fdc5c20.jpg?v=1785816077"},{"product_id":"24-vac-3-4-in-pro-press-zone-valve-with-18-in-lead-wire","title":"Honeywell Home V8043A1312\/U 24 Vac 3\/4 in Pro Press Zone Valve with 18 in Lead Wire","description":"\u003cp\u003eThe V8043A1312 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch Pro Press valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch Pro Press connections tie the valve into the supply piping, and the V8043A1312 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-50-60-hz-replacement-head-for-v8043a\"\u003eHoneywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement head for V8043A\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-521\/U Replacement Head for V8043A, 5000 series, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043A1312\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Pro press\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826, CSA Certified: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e6.78 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e2.34 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003ePro Press\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.0 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e120 PSI, 827 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329566823,"sku":"HONE-V8043A1312\/U","price":176.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043AP-c4-6.jpg?v=1785816078"},{"product_id":"24-vac-3-4-in-sweat-n-c-quickfit-zone-valve","title":"Honeywell Home V8043A5029\/U 24 Vac 3\/4 in Sweat N.C. QuickFit® Zone Valve","description":"\u003cp\u003eThe V8043A5029 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043A5029 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-vac-50-60-hz-replacement-head-for-v8043a\"\u003eHoneywell Home 40003916-021\/U 24 Vac, 50\/60 Hz Replacement head for V8043A\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043a-5000-series-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-521\/U Replacement Head for V8043A, 5000 series, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043A5029\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA C\/US: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi, 2068 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for the V8043 5000 Series Zone Valve (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/68-3092.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal Sheet for V8043 5000 Series Zone Valves (English)\u003c\/a\u003e (0.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329599591,"sku":"HONE-V8043A5029\/U","price":145.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E5012-c1-6.jpg?v=1785816079"},{"product_id":"24-vac-1-2-in-sweat-n-o-zone-valve","title":"Honeywell Home V8043B1019\/U 24 Vac 1\/2 in Sweat N.O. Zone Valve","description":"\u003cp\u003eThe V8043B1019 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally open\u003c\/strong\u003e. It passes flow with no power applied and closes when the actuator is energized. Normally open is the right choice where a zone has to keep circulating if the control power drops — freeze protection on an exposed loop is the usual reason to specify it.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch sweat connections tie the valve into the supply piping, and the V8043B1019 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043b-24-v-ac-50-60-hz-normally-open\"\u003eHoneywell Home 40003916-027\/U Replacement Head for V8043B, 24 V AC, 50\/60 Hz, Normally Open\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043B1019\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/63-8702.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWhole Home Hydronic Heating and Potable Water Solutions (English)\u003c\/a\u003e (15.8MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329632359,"sku":"HONE-V8043B1019\/U","price":150.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c10-6_3ed828c6-2e25-48c4-994a-9508638b5fcb.jpg?v=1785816081"},{"product_id":"24-vac-3-4-in-sweat-n-o-zone-valve","title":"Honeywell Home V8043B1027\/U 24 Vac 3\/4 in Sweat N.O. Zone Valve","description":"\u003cp\u003eThe V8043B1027 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally open\u003c\/strong\u003e. It passes flow with no power applied and closes when the actuator is energized. Normally open is the right choice where a zone has to keep circulating if the control power drops — freeze protection on an exposed loop is the usual reason to specify it.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043B1027 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043b-24-v-ac-50-60-hz-normally-open\"\u003eHoneywell Home 40003916-027\/U Replacement Head for V8043B, 24 V AC, 50\/60 Hz, Normally Open\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043B1027\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally open\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/63-8702.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWhole Home Hydronic Heating and Potable Water Solutions (English)\u003c\/a\u003e (15.8MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329665127,"sku":"HONE-V8043B1027\/U","price":160.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c10-6_da3a6d76-7017-4027-b6fb-f72133a3dc3a.jpg?v=1785816083"},{"product_id":"24-vac-1-2-in-sweat-n-c-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1004\/U 24 Vac 1\/2 in Sweat N.C. Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1004 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch sweat connections tie the valve into the supply piping, and the V8043E1004 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1004\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329796199,"sku":"HONE-V8043E1004\/U","price":130.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c36-6.jpg?v=1785816085"},{"product_id":"24-vac-3-4-in-sweat-n-c-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1012\/U Zone Valve, 24 VAC, 3\/4 in Sweat, Normally Closed, 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1012 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043E1012 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1012\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351329828967,"sku":"HONE-V8043E1012\/U","price":138.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E-c41-6.jpg?v=1785816087"},{"product_id":"24-vac-1-in-sweat-n-c-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1020\/U 24 Vac 1 in Sweat N.C. Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1020 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1-inch sweat connections tie the valve into the supply piping, and the V8043E1020 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1020\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330451559,"sku":"HONE-V8043E1020\/U","price":161.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E-c41-6_84df075c-1bee-4947-aff1-a63ecf98a1bf.jpg?v=1785816089"},{"product_id":"24-vac-3-4-in-sweat-n-c-zone-valve-with-18-in-lead-wires-hone-v8043e1061-u","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. Zone Valve with 18 in Lead Wires V8043E1061\/U","description":"\u003cp\u003eThe V8043E1061 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043E1061 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1061\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e8 psi, 55 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e8 Cv; 6.9 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330484327,"sku":"HONE-V8043E1061\/U","price":140.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E-c41-6_216254f7-21a4-4f8b-887e-a8c0d9297169.jpg?v=1785816091"},{"product_id":"24-vac-1-2-in-invert-flare-n-c-quickfit-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1129\/U 24 Vac 1\/2 in Invert-Flare N.C. QuickFit Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1129 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch invert-flare valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch invert-flare connections tie the valve into the supply piping, and the V8043E1129 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1129\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Invert-flare\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.63 in, 92 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eInverted Flare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330517095,"sku":"HONE-V8043E1129\/U","price":144.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c52-6.jpg?v=1785816091"},{"product_id":"24-vac-1-in-npt-n-c-quickfit-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1137\/U 24 Vac 1 in NPT N.C. QuickFit Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1137 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1-inch NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1-inch NPT connections tie the valve into the supply piping, and the V8043E1137 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1137\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e6.5 psi, 45 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e10 Cv; 8.6 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330549863,"sku":"HONE-V8043E1137\/U","price":172.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c51-6.jpg?v=1785816092"},{"product_id":"24-vac-3-4-in-npt-n-c-quickfit-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E1145\/U 24 Vac 3\/4 in NPT N.C. QuickFit Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E1145 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch NPT connections tie the valve into the supply piping, and the V8043E1145 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E1145\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330582631,"sku":"HONE-V8043E1145\/U","price":150.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c52-6_0ec2d838-1b6c-4816-b5e0-3fd534c76903.jpg?v=1785816093"},{"product_id":"24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-with-18-in-lead-wires","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve with 18 in Lead Wires V8043E5012\/U","description":"\u003cp\u003eThe V8043E5012 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043E5012 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E5012\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA Certified: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.38 in, 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi, 2068 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for the V8043 5000 Series Zone Valve (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330615399,"sku":"HONE-V8043E5012\/U","price":150.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E5012-c1-6_f51ca7fa-23f7-4615-954d-fc478d3b99f5.jpg?v=1785816094"},{"product_id":"24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-with-18-in-lead-wires-hone-v8043e5061-u","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve with 18 in Lead Wires V8043E5061\/U","description":"\u003cp\u003eThe V8043E5061 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043E5061 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E5061\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA Certified: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.38 in, 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e8 psi, 55 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e8 Cv; 6.9 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi, 2068 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for the V8043 5000 Series Zone Valve (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330648167,"sku":"HONE-V8043E5061\/U","price":152.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E5012-c1-6_c01790e3-2fd7-4173-b814-c6d446a1f6ea.jpg?v=1785816095"},{"product_id":"24-vac-1-in-sweat-n-c-quickfit-zone-valve-with-18-in-lead-wires","title":"Honeywell Home V8043E5079\/U 24 Vac 1 in Sweat N.C. QuickFit Zone Valve with 18 in Lead Wires","description":"\u003cp\u003eThe V8043E5079 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1-inch sweat connections tie the valve into the supply piping, and the V8043E5079 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. Lead wires are 18 inches long, enough to reach a nearby junction box or zone panel terminal without splicing in the tight space above a boiler. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043E5079\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead wires:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA Certified: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.38 in, 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e8 psi, 55 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e8 Cv; 6.9 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi, 2068 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for the V8043 5000 Series Zone Valve (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00596EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351330680935,"sku":"HONE-V8043E5079\/U","price":171.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c40-6.jpg?v=1785816097"},{"product_id":"24-vac-1-in-sweat-n-c-zone-valve","title":"Honeywell Home V8043F1051\/U 24 Vac 1 in Sweat N.C. Zone Valve","description":"\u003cp\u003eThe V8043F1051 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1-inch sweat connections tie the valve into the supply piping, and the V8043F1051 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043f-with-end-switch-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-048\/U Replacement Head for V8043F, with End Switch, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043F1051\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Recognized: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass, Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 101 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv|3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10926EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C,D,F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/95C-10002EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C, D, F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00597EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 1000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (1.1MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331205223,"sku":"HONE-V8043F1051\/U","price":173.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c54-6.jpg?v=1785816098"},{"product_id":"24-vac-3-4-in-sweat-n-c-zone-valve","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. Zone Valve V8043F1093\/U","description":"\u003cp\u003eThe V8043F1093 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043F1093 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043f-with-end-switch-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-048\/U Replacement Head for V8043F, with End Switch, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043F1093\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Loss Action\u003c\/th\u003e\n\u003ctd\u003eValve Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Recognized: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass, Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4 in, 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e8 psi, 55 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFail-Safe Operation Type\u003c\/th\u003e\n\u003ctd\u003eSpring return to close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e8 Cv|6.9 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Control Signal\u003c\/th\u003e\n\u003ctd\u003eTwo position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eActuator Opening Time\u003c\/th\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/33-00402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043 Zone Valves with Press Connection (English, French)\u003c\/a\u003e (1.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10926EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C,D,F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/95C-10002EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C, D, F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10000\/03-00563.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the Hydronic Products with Press Fittings (English)\u003c\/a\u003e (9.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/1\/63-9367.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure for the V8043 1000 Series Zone Valve (English)\u003c\/a\u003e (1.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10016\/33-00597EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eV8043C, D, F \u0026amp; G 1000 Series Motorized Zone Valves Submittal Sheet (English, French)\u003c\/a\u003e (1.1MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331237991,"sku":"HONE-V8043F1093\/U","price":154.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043-c54-6_26b2bfe9-1bb3-43b8-bba4-c720ddcab4ad.jpg?v=1785816098"},{"product_id":"24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-hone-v8043f5036-u","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve V8043F5036\/U","description":"\u003cp\u003eThe V8043F5036 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8043F5036 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8043f-with-end-switch-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-048\/U Replacement Head for V8043F, with End Switch, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8043F5036\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eCSA C\/US: File 1322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eEnd switch enclosure, Manual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.38 in, 111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 89 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e3.5 Cv; 3 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e50 °F, 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e300 psi, 2068 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eTwo-way, Straight Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10005\/95-6983EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V4043, V4044 Valves; V8043, V8044 Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10932.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V8043A, V8043E, V8043F 5000 Series Zone Valves (English)\u003c\/a\u003e (0.4MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/95C-10938EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C, D, F \u0026amp; G 5000 Series Motorized Zone Valves (English, French)\u003c\/a\u003e (1.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10926EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C,D,F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/95C-10002EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8043C, D, F \u0026amp; G Motorized Zone Valves (English, French)\u003c\/a\u003e (1.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/50-9210.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell Sheet for the V8043 5000 Series Zone Valve (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331270759,"sku":"HONE-V8043F5036\/U","price":164.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8043E5012-c1-6_826c0340-411c-48f2-bc44-78cc8401adfd.jpg?v=1785816100"},{"product_id":"24-vac-1-2-in-sweat-n-c-quickfit-zone-valve","title":"Honeywell Home V8044A1010\/U 24 Vac 1\/2 in Sweat N.C. QuickFit Zone Valve","description":"\u003cp\u003eThe V8044A1010 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch sweat connections tie the valve into the supply piping, and the V8044A1010 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8044a-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-046\/U Replacement Head for V8044A, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8044A1010\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e0.86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e4 Cv|3.4 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-3101.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8044A, V8044B, V8044E 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331303527,"sku":"HONE-V8044A1010\/U","price":150.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8044-c8-6_9e9f41bd-3b09-4c60-9ad1-d4884ad13e8e.jpg?v=1785816100"},{"product_id":"24-vac-3-4-in-sweat-n-c-quickfit-zone-valve-hone-v8044a1044-u","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. QuickFit Zone Valve V8044A1044\/U","description":"\u003cp\u003eThe V8044A1044 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8044A1044 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8044a-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-046\/U Replacement Head for V8044A, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8044A1044\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.63 in, 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.69 in, 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e10 psi, 69 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e7.0 Cv|6 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-3101.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8044A, V8044B, V8044E 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331401831,"sku":"HONE-V8044A1044\/U","price":166.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/v8044-c1-6_6db75734-1299-4221-9bcf-c8da3901a566.jpg?v=1785816102"},{"product_id":"24-vac-1-2-in-npt-nc-quickfit-zone-valve","title":"Honeywell Home V8044A1135\/U 24 Vac 1\/2 in NPT NC QuickFit Zone Valve","description":"\u003cp\u003eThe V8044A1135 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 1\/2-inch NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 1\/2-inch NPT connections tie the valve into the supply piping, and the V8044A1135 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8044a-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-046\/U Replacement Head for V8044A, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8044A1135\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.88 in, 124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e1.13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e4 Cv|3.4 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-3101.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8044A, V8044B, V8044E 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331434599,"sku":"HONE-V8044A1135\/U","price":160.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/V8044-c11-6.jpg?v=1785816103"},{"product_id":"24-vac-3-4-in-npt-n-c-quickfit-zone-valve","title":"Honeywell Home V8044A1143\/U 24 Vac 3\/4 in NPT N.C. QuickFit Zone Valve","description":"\u003cp\u003eThe V8044A1143 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch NPT valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch NPT connections tie the valve into the supply piping, and the V8044A1143 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThis is a \u003cstrong\u003eQuickFit\u003c\/strong\u003e model: the actuator head releases from the valve body without breaking the piping connection, so a failed motor is changed out without draining the system or unsoldering anything.\u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-for-v8044a-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-046\/U Replacement Head for V8044A, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8044A1143\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Npt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickFit actuator:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e4.88 in, 124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e2.38 in, 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e3.75 in, 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e20 psi, 138 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e4 Cv|3.4 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-3101.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8044A, V8044B, V8044E 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331467367,"sku":"HONE-V8044A1143\/U","price":170.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/v8044-c1-6_e4c37520-8be7-488e-8329-d46294fa0306.jpg?v=1785816104"},{"product_id":"24-vac-3-4-in-sweat-n-c-zone-valve-hone-v8044e1011-u","title":"Honeywell Home 24 Vac 3\/4 in Sweat N.C. Zone Valve V8044E1011\/U","description":"\u003cp\u003eThe V8044E1011 is a two-position hydronic zone valve from Resideo, the brand that carries the Honeywell Home line of residential heating controls. It pairs a motorized actuator with a 3\/4-inch sweat valve body to start and stop hot water flow to a single heating zone on a call from a thermostat or zone panel.\u003c\/p\u003e\u003cp\u003eThe valve is \u003cstrong\u003enormally closed\u003c\/strong\u003e. It stays shut until the actuator is energized and returns to the closed position when power is removed, so a zone drops out on a power failure or a thermostat fault instead of running unattended. That is the safer default on a boiler loop feeding radiators, convectors, finned baseboard, or in-floor radiant tubing.\u003c\/p\u003e\u003cp\u003eThe 3\/4-inch sweat connections tie the valve into the supply piping, and the V8044E1011 handles supply water at operating pressures up to \u003cstrong\u003e300 psi\u003c\/strong\u003e. \u003c\/p\u003e\u003cp\u003eThe V8043 and V4043 series have been the reference zone valves in North American hydronic heating for decades, and most contractors still order them by the original Honeywell part number. The actuator head is field-replaceable, so a burned-out motor does not mean cutting the body out of the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReplacement head and motor for this valve\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/replacement-head-with-end-switch-for-v8044e-24-v-ac-50-60-hz\"\u003eHoneywell Home 40003916-026\/U Replacement Head with End Switch for V8044E, 24 V AC, 50\/60 Hz\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/24-volt-replacement-motor-for-v8043-and-v8044\"\u003eHoneywell Home 802360JA\/U 24-Volt Replacement Motor for V8043 and V8044\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e V8044E1011\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve action:\u003c\/strong\u003e Normally closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection size:\u003c\/strong\u003e 3\/4 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Sweat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax operating pressure:\u003c\/strong\u003e 300 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valves\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Ball Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Disc Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals and Standards\u003c\/th\u003e\n\u003ctd\u003eUL Listed: File MH11826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eManual Opener\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Length\u003c\/th\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Width\u003c\/th\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient Operating Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e125 °F, 52 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eSweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDifferential pressure for close-off (Max)\u003c\/th\u003e\n\u003ctd\u003e10 psi, 69 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlow Coefficient\u003c\/th\u003e\n\u003ctd\u003e7.0 Cv|6 Kvs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Min)\u003c\/th\u003e\n\u003ctd\u003e40 °F, 5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMedia Temperature (Max)\u003c\/th\u003e\n\u003ctd\u003e200 °F, 93 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStatic Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e125 psi, 862 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Body Pattern\u003c\/th\u003e\n\u003ctd\u003eThree-way, Diverting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Plug Material\u003c\/th\u003e\n\u003ctd\u003eBuna-N (NBR) Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Seat Material\u003c\/th\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Start Position\u003c\/th\u003e\n\u003ctd\u003ePort A Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10015\/60-2133.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Data for V4043, V4044, V8043, V8044 Motorized Valves (English)\u003c\/a\u003e (2.1MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10013\/68-3101.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for V8044A, V8044B, V8044E 1000 Series Diverting Valve (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10019\/63-9379.pdf\" target=\"_blank\" rel=\"noopener\"\u003eResideo Hydronic Heating Solutions Brochure (English)\u003c\/a\u003e (4.5MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351331500135,"sku":"HONE-V8044E1011\/U","price":172.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/v8044-c1-6_bd160ee0-457c-461a-82da-166c3a2a4268.jpg?v=1785816105"},{"product_id":"vc-series-replacement-cartridge-for-2-port-zone-valves","title":"Honeywell Home VCZZ1000\/U VC Series Replacement Cartridge for 2-port Zone Valves","description":"\u003cp\u003eReplacement cartridge for Honeywell Home VC series 2-way zone valves.\u003c\/p\u003e\u003cp\u003eThe VC design puts the seat, plug and seal inside a removable cartridge. A valve that no longer shuts off tight is rebuilt from the top, with the body left soldered or threaded in the line and the actuator reused.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat a complete VC zone valve takes:\u003c\/strong\u003e a valve body, a cartridge, and an actuator, ordered separately. This listing is the cartridge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVC valve bodies and actuators this cartridge fits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-way-1-2-in-sweat-vc-valve-assembly-3-5-cv-and-linear-flow\"\u003eHoneywell Home VCZAA1100\/E 2-way 1\/2 in Sweat VC Valve Assembly 3.5 Cv and linear flow\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-way-3-4-in-fnpt-vc-valve-assy-4-7-cv-and-linear-flow\"\u003eHoneywell Home 2-way 3\/4 in fNPT VC Valve Assy 4.7 Cv and linear flow VCZAL1100\/E\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-way-3-4-in-fnpt-vc-valve-assy-4-7-cv-and-linear-flow-hone-vczal3100-u\"\u003eHoneywell Home 2-way 3\/4 in fNPT VC Valve Assy 4.7 Cv and linear flow VCZAL3100\/U\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-way-1-in-fnpt-vc-valve-assy-6-6-cv-and-linear-flow\"\u003eHoneywell Home VCZAR1100\/U 2-way 1 in fNPT VC Valve Assy 6.6 Cv and linear flow\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/2-way-1-2-in-fnpt-vc-valve-assembly-3-5-cv-and-linear-flow\"\u003eHoneywell Home VCZBB1100\/U 2-way 1\/2 in fNPT VC Valve Assembly 3.5 Cv and linear flow\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell Home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e VCZZ1000\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 2-way\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eValve Cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eUse in cold, warm, and hot water applications. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eTwo-way VC Cartridge Valves with 14 lbf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Type\u003c\/th\u003e\n\u003ctd\u003eCartridge Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Flow Characteristic\u003c\/th\u003e\n\u003ctd\u003eQuick Opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Travel\u003c\/th\u003e\n\u003ctd\u003e0.4 in, 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve Stem Material\u003c\/th\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControlled Media\u003c\/th\u003e\n\u003ctd\u003e60% Glycol Mixture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Diameter\u003c\/th\u003e\n\u003ctd\u003e1.5 in, 37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Height\u003c\/th\u003e\n\u003ctd\u003e2.56 in, 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10949.pdf\" target=\"_blank\" rel=\"noopener\"\u003eVC1000, VC6000 Series Replacement Cartridges for 2-Way \u0026amp; 3-Way VC Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":44351332253799,"sku":"HONE-VCZZ1000\/U","price":33.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/vczz1000-ge25cohres.jpg?v=1785816128"},{"product_id":"resideo-272748ab-u-zone-valve-motor-24-v","title":"Honeywell Home 272748AB\/U Zone Valve Motor, 24 V","description":"\u003cp\u003e24 V replacement motor for zone valves.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 272748AB\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Motor for 24 V AC V Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8043\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123150\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e MX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Motor for 24 V AC V Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eElectric Motorized Valves for Replacement Motors for Electric Motorized Valves (English, French)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331135574119,"sku":"HONE-272748AB\/U","price":49.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/272748AB-c1-6.jpg?v=1790429218"},{"product_id":"resideo-272748abp-u-zone-valve-motor-24-v-60-hz-trade-class-a","title":"Honeywell Home 272748ABP\/U Zone Valve Motor, 24 V 60 Hz, Trade Class A","description":"\u003cp\u003e24 V, 60 Hz replacement motor for zone valves, Trade Class A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 272748ABP\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Motor for 24 V AC V Series Zone Valves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V4043, V4044\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e Motor Mounting Screw, Lead Connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 50 Hz, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Length:\u003c\/strong\u003e 6 in, 152 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Leads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123167\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Motor for 24 V AC V Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV4043, V4044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eMotor Mounting Screw, Lead Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e6 in, 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10402EF.pdf\" target=\"_blank\" rel=\"noopener\"\u003eElectric Motorized Valves for Replacement Motors for Electric Motorized Valves (English, French)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331135606887,"sku":"HONE-272748ABP\/U","price":71.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/272748AB-c1-6_3e2a516b-0394-4f94-9afc-571f02d89441.jpg?v=1790429220"},{"product_id":"resideo-40003916-008-u-zone-valve-actuator-for-v8044c-24-vac-50-hz-1-m-cable","title":"Honeywell Home 40003916-008\/U Zone Valve Actuator for V8044C, 24 VAC 50 Hz, 1 m Cable","description":"\u003cp\u003eZone valve actuator for V8044C valves with a 1 m cable, rated 24 VAC, 50 Hz.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-008\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Motor for V8044C Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8044C1024, V8044C1040, V8044C1065, V8044C1081, V8044C1099\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves for hydronic heating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire and Smoke Rated:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Length:\u003c\/strong\u003e 1 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Leadwire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123723\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Motor for V8044C Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8044C1024, V8044C1040, V8044C1065, V8044C1081, V8044C1099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeadwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331139145831,"sku":"HONE-40003916-008\/U","price":100.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_3d2b896e-e218-4864-92cf-bdd330502456.jpg?v=1790429281"},{"product_id":"resideo-40003916-011-u-replacement-actuator-for-v8043c-1000-series-zone-valves-2-way-normally-closed","title":"Honeywell Home 40003916-011\/U Replacement Actuator for V8043C 1000 Series Zone Valves, 2-Way, Normally Closed","description":"\u003cp\u003eReplacement actuator for V8043C \"1000\" series zone valves; 2-way, normally closed, with 18 in leads and Heyco strain relief, 24 V\/60 Hz.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-011\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Powerhead for V8043A,C Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8043A1173, V8043C1033, V8043C1041, V8043C1058, V8043C1066, V8043C1074, V8043C1116, V8043C1124\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves for hydronic heating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e N.C. configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire and Smoke Rated:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Length:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Leadwire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123754\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043A,C Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043A1173, V8043C1033, V8043C1041, V8043C1058, V8043C1066, V8043C1074, V8043C1116, V8043C1124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eN.C. configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeadwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331139178599,"sku":"HONE-40003916-011\/U","price":105.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_925d859a-e62b-4f72-b692-819d4d026641.jpg?v=1790429282"},{"product_id":"resideo-40003916-012-u-replacement-actuator-for-v8043g-1000-series-zone-valves-2-way-n-c-end-switch","title":"Honeywell Home 40003916-012\/U Replacement Actuator for V8043G 1000 Series Zone Valves, 2-Way, N.C., End Switch","description":"\u003cp\u003eReplacement actuator for V8043G \"1000\" series zone valves; 2-way, normally closed, with end switch, 18 in leads and Heyco strain relief, 24 V\/60 Hz.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-012\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Powerhead for V8043E,G Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8043E1129, V8043G1000, V8043G1018, V8043G1026, V8043G1034, V8043G1109, V8043G1125, V8043G1133\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves for hydronic heating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e N.C. configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 50 Hz, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Switch Function and Capacity:\u003c\/strong\u003e SPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Switches:\u003c\/strong\u003e SPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire and Smoke Rated:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Length:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Leadwire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123761\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043E,G Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043E1129, V8043G1000, V8043G1018, V8043G1026, V8043G1034, V8043G1109, V8043G1125, V8043G1133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eN.C. configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnd Switch Function and Capacity\u003c\/th\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnd Switches\u003c\/th\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeadwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331139965031,"sku":"HONE-40003916-012\/U","price":111.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_6c8c4809-d074-4315-8e91-e868ab90f446.jpg?v=1790429283"},{"product_id":"resideo-40003916-013-u-replacement-actuator-for-v8043f-1000-series-zone-valves-2-way-n-c-end-switch","title":"Honeywell Home 40003916-013\/U Replacement Actuator for V8043F 1000 Series Zone Valves, 2-Way, N.C., End Switch","description":"\u003cp\u003eReplacement actuator for V8043F \"1000\" series zone valves; 2-way, normally closed, with end switch and screw terminals, 24 V\/60 Hz.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-013\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Powerhead for V8043F Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8043F1119, V8043F1127, V8043F1135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves for hydronic heating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e N.C. Configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Switch Function and Capacity:\u003c\/strong\u003e SPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd Switches:\u003c\/strong\u003e SPST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire and Smoke Rated:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123778\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043F Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043F1119, V8043F1127, V8043F1135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eN.C. Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnd Switch Function and Capacity\u003c\/th\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnd Switches\u003c\/th\u003e\n\u003ctd\u003eSPST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331139997799,"sku":"HONE-40003916-013\/U","price":119.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_c8f6de9f-2a54-4475-9c2d-2141f63839a5.jpg?v=1790429283"},{"product_id":"resideo-40003916-014-u-replacement-actuator-for-v8043d-1000-series-zone-valves-2-way-normally-open","title":"Honeywell Home 40003916-014\/U Replacement Actuator for V8043D 1000 Series Zone Valves, 2-Way, Normally Open","description":"\u003cp\u003eReplacement actuator for V8043D \"1000\" series zone valves; 2-way, normally open, with 18 in leads and Heyco strain relief, 24 V\/60 Hz.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Resideo (Honeywell Home)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part #:\u003c\/strong\u003e 40003916-014\/U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Replacement Powerhead for V8043D Series Zone Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor Use With:\u003c\/strong\u003e V8043D1023, V8043D1031, V8043D1049, V8043D1064, V8043D1072, V8043D1080, V8043D1156, V8043D1197, V8043D1205\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e V Series Zone Valves for hydronic heating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncludes:\u003c\/strong\u003e N.O. configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency:\u003c\/strong\u003e 50 Hz, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire and Smoke Rated:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Length:\u003c\/strong\u003e 18 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Leadwire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Metallic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 085267123785\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e HU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Zone Valve Replacement Heads\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003ch3\u003eFull Specifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eReplacement Powerhead for V8043D Series Zone Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eV8043D1023, V8043D1031, V8043D1049, V8043D1064, V8043D1072, V8043D1080, V8043D1156, V8043D1197, V8043D1205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd\u003eV Series Zone Valves for hydronic heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eN.O. configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply Frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire and Smoke Rated\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Length\u003c\/th\u003e\n\u003ctd\u003e18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd\u003eLeadwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eMetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/69-0404.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916 Powerhead (English)\u003c\/a\u003e (0.7MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10933.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-510 Series Replacement Powerhead (English)\u003c\/a\u003e (0.9MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10011\/95C-10944.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for 40003916-500 Series Replacement Powerhead (English)\u003c\/a\u003e (0.6MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10655.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation Instructions for the 40003916 Replacement Powerhead (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10014\/95C-10656.pdf\" target=\"_blank\" rel=\"noopener\"\u003e40003916-003 Replacement Powerhead for V4073A Mid-Position Valves Installation Instructions (English)\u003c\/a\u003e (0.3MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-001U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-001U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.resideo.com\/damroot\/Original\/10003\/40003916-003U_doc-ml0h.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Not Required Memo 40003916-003U_doc-ml0h.pdf\u003c\/a\u003e (0.2MB PDF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Honeywell Home","offers":[{"title":"Default Title","offer_id":50331140063335,"sku":"HONE-40003916-014\/U","price":109.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/2253\/3479\/files\/40003916-c12-6_c58a010c-6f2a-44f4-aa67-5e5e9ca3b277.jpg?v=1790429286"}],"url":"https:\/\/www.thehousesupplier.com\/collections\/honeywell-zone-valves.oembed?page=2","provider":"The House Supplier","version":"1.0","type":"link"}