PVC Schedule 40 pressure fittings, sizes 1/2" through 8", in socket x socket, spigot x socket, all-socket, socket x FPT and spigot x FPT.
Schedule 40 shares an outside diameter with Schedule 80 but has a thinner wall, a larger bore and a lower pressure rating. Pressure rating also falls with diameter — a 1/2" SCH 40 fitting is rated far higher than a 4" one, which surprises people sizing an irrigation main by material alone rather than by the published rating for that size.
Temperature matters more than pressure in most failures. PVC loses roughly half its rated strength by 110°F and is not approved for hot water at all; CPVC is the material for that.
A spigot end is sized to enter a socket, so a spigot x socket bushing reduces without adding a coupling. Joints are primed and solvent cemented, both surfaces, quarter-turned and left to cure.
Checking a rating by size? Our PVC & CPVC pipe dimensions and specifications list OD, wall, ID and maximum psi for every Schedule 40 size, with the temperature derating factors.
Predominantly Charlotte Pipe, with Nibco.