Dimensions, pressure ratings, standards, joining methods and part numbering for the piping systems, controls and appliances we stock — the numbers you need on the job, not a catalogue. Every table is sourced to its ASTM or ASME standard, or to the manufacturer's published specification.

Copper Pipe & Tube

Type K, L and M dimensions per ASTM B88, plus DWV and ACR.

  • OD, wall and ID for K, L and M, 1/4" to 4"
  • Colour code and which type your code allows
  • Hard vs soft temper
  • Why ACR sizing does not match CTS
  • Lead-free solder requirements

PVC & CPVC Pipe

Schedule 40, Schedule 80, DWV and CPVC CTS dimensions and ratings.

  • OD, wall, ID and psi by schedule, 1/2" to 8"
  • How the pressure rating is derived
  • Temperature derating, 73°F to 140°F
  • DWV vs sewer & drain vs pressure pipe
  • Solvent cement by material

PEX Tubing

PEX-a and PEX-b dimensions, ratings and fitting compatibility.

  • Dimensions per ASTM F876
  • Pressure and temperature ratings
  • Minimum bend radius and thermal expansion
  • F1960, F1807, F2159 and press compatibility
  • Oxygen barrier and when it is required

Press Fittings

Press systems for copper, carbon steel, stainless and ACR.

  • Copper tube dimensions per ASTM B88
  • EPDM vs HNBR vs FKM seal selection
  • ASME B16.51 and ANSI LC 4 / CSA 6.32
  • Jaw and profile compatibility
  • Installation sequence and depth marking

Black Iron Pipe & Fittings

NPT thread engagement, Class 150 ratings and Schedule 40 dimensions.

  • Threads per inch and L1 hand-tight by size
  • Class 150: 300 psi WOG, 150 psi saturated steam
  • Why one union drops the run to 150 psi
  • Black vs galvanized, and what NFPA 54 actually says
  • Nipple lengths, close nipples and ASTM A733

Valve Types & Pressure Ratings

Ball, gate, globe and check valves compared, with the ratings we actually stock.

  • What WOG and SWP mean, and which one governs
  • Ball vs gate — where each one belongs
  • Full port vs standard port, and when it matters
  • Check valve body styles and mounting limits
  • Backflow, PRV and T&P relief side by side

Y-Strainers & Basket Strainers

Mesh selection, orientation and body ratings for pipeline strainers.

  • Y and wye are the same device
  • Mesh to microns: 20, 40, 80 and 1/16" perforated
  • Why the big sizes get a coarser screen, not a finer one
  • Cap down, and flow down on a vertical
  • Bronze 300 psi, cast iron 500 psi, press 200 psi

Roof Drain Sizing & Installation

Sizing a flat or low-slope roof by area or by flow, with overflow rules and the install sequence.

  • Leader capacity for 3", 4", 6" and 8" by rainfall rate
  • Total GPM = 0.0104 × rainfall rate × roof area
  • IPC 1108.1: overflow inlet 2" to 4" above the low point
  • Primary, combination, scupper, promenade and siphonic
  • Signs a drain is failing, and the parts people forget

Water Leak Detection

Point sensors, appliance shut-off kits and whole-house valves, and how to choose between them.

  • Size the valve to the main, not to a branch
  • Stocked sizes: 1/2", 3/4", 1" and 1-1/4" NPT
  • Where each device installs, and where sensors go
  • Freeze and humidity monitoring on the same device
  • What each tier costs, sensor to whole house

Honeywell to Resideo

Part number cross-reference for Honeywell Home and Resideo controls.

  • What changed in the 2018 spin-off, and what did not
  • Series index: L, V, VR, Q, ZD, TH and the rest
  • Which series covers which control type
  • Where the number genuinely does change
  • Voltage and aquastat well selection

Navien Model Comparison

Every Navien tankless, combi and boiler we stock, side by side.

  • Gas input and UEF by model
  • Hot water flow at 35°F, 45°F and 67°F rise
  • How to read the flow-rate columns
  • NPE-A2 vs NPE-S2 — what the difference buys
  • Condensing vs non-condensing venting

Choosing a material

Three constraints usually decide it, in this order:

  • Temperature. PVC stops at 140°F and holds only 22% of its rating there — it is not a hot water material. CPVC reaches 200°F, PEX and copper handle domestic hot water comfortably.
  • Code. Type M copper is prohibited underground in many jurisdictions. DWV and sewer pipe are not interchangeable. Gas press fittings need their own listing. What is legal to buy is not always legal to install.
  • Joining. Whether the building allows a flame decides more retrofit jobs than material cost does. Press, push and crimp all avoid hot work permits.