Honeywell to Resideo Part Number Cross-Reference
If you are holding an older manual, a service tag, or a parts list that says Honeywell and you cannot find the part under that name, this page explains what happened and how to find it.
What changed, and what did not
Honeywell completed the spin-off of Resideo Technologies on 29 October 2018. The Honeywell Homes product portfolio went to Resideo as a stand-alone company, and Honeywell licensed the Honeywell Home brand to Resideo under a long-term agreement. That is why the brand still appears on the box while the company behind it is Resideo.
The practical consequence for anyone ordering parts: the model numbering carried over. Across the 606 Resideo parts we stock, the numbers follow the same historic Honeywell series they always did. An L8148E aquastat relay is still listed as an L8148E. A VR8345Q universal gas valve is still a VR8345Q. A ZD zone damper is still a ZD.
So the number in your old manual is almost always the number to order. You are not looking for a replacement part — you are looking for the same part with a different company name on the label.
Part number series index
Every Honeywell control series we carry, what it covers, and where it sits in the catalog.
Hydronic controls
| Series | What it is | Example | Where to find it |
|---|---|---|---|
| L | Aquastat relays, limit controls | L8148E1299 | Aquastats and wells, fan and limit controllers |
| V | 2-way zone valves, radiator valves | V8043, V110D1016 | 2-way zone valves, thermostatic radiator valves |
| VC / VU | Zone valve powerheads, fan coil valves | VC8110ZZ32, VU844A1060 | Replacement heads, fan coil zone valves |
| VCZZ | Zone valve internal parts | VCZZ7100 | Zone valve parts |
| AM | Thermostatic mixing valves | AM100-002RP | Mixing valves |
| DS / K | Pressure reducing and fill valves | DS06-105-SUT-LF | Pressure reducing valves |
| PV / HS | Air separators, hydraulic separators | PV150P | Air separators |
| TK | Boiler trim kits | TK30PV125SNK | Boiler trim kits |
Gas and ignition
| Series | What it is | Example | Where to find it |
|---|---|---|---|
| VR / SV | Gas valves and gas controls | VR8345Q4563, SV9641M4510 | Gas valves |
| Q | Pilot assemblies, thermocouples, ignition components | Q4100C9068 | Gas ignition components, thermocouples |
| S | Ignition control modules | S8910U3000 | Gas ignition components |
| R | Oil burner primary controls | R8184G | Oil burner controls |
Zoning and switching
| Series | What it is | Example | Where to find it |
|---|---|---|---|
| ZD / ARD | Rectangular and round zone dampers | ZD8X20TZ, ARD7TZ | Zone dampers |
| HZ | Forced air zone panels | HZ322 | Forced air zone panels |
| HPZC / HPSR | Zone valve controllers, switching relays | HPZC106 | Switching relays |
| R | Fan centers, general purpose relays | R8285A1048, R841D1036 | Relays |
| AT | Low-voltage transformers | AT150F1022 | Transformers |
| DP | Definite purpose contactors | DP3040C5001 | Contactors |
Thermostats and air
| Series | What it is | Example | Where to find it |
|---|---|---|---|
| TH | Current thermostat line — T3, T4, T6 Pro and PRO series | TH3110U2008, TH114-A-240D-B | Thermostats |
| T / TL | Legacy and line-voltage thermostats | T812A1010 | Non-programmable, line voltage |
| THP / C | RedLINK accessories, sensors | C7735A1000 | Thermostat accessories |
| F / FC | Media air cleaners and filters | FC40R1029 | Air cleaners and filters |
| HC / HM | Humidifier pads and units | HC26E1004 | Humidifiers and dehumidifiers |
| VWS | Water leak detection and shutoff | VWS1000 | Leak detection valves |
Where the number genuinely does change
The rebrand did not renumber parts, but parts do get superseded over time, and that happens independently of what is written on the box. Two cases to watch:
Gas valves and ignition assemblies. These are matched to the appliance and often to a serial range within a single model, because the manufacturer revises the component without changing the appliance name. Order from the data plate on the equipment, not from the model name of the furnace or boiler.
Discontinued controls with a functional replacement. Where an older control is no longer produced, the replacement usually differs in more than the number — terminal layout, switch action or voltage may change. Confirm the specification rather than assuming a drop-in.
Two checks before you order
Voltage. Low-voltage 24V controls drive a system through a transformer and relay and cover most gas and hydronic equipment. Line voltage switches 120V or 240V directly and belongs to electric baseboard and radiant. Connecting one to the wrong system is a fire risk, not a malfunction.
Aquastat and well together. An aquastat has to be paired with the correct immersion well, seated to the bottom with conducting paste. Well length and bulb diameter have to match, or the control reads the air in the well and responds late.
The full range is in the Resideo collection — over 600 controls and parts in stock.