If you are holding an older manual, a service tag, or a parts list that says Honeywell and you cannot find the part under that name, this page explains what happened and how to find it.

What changed, and what did not

Honeywell completed the spin-off of Resideo Technologies on 29 October 2018. The Honeywell Homes product portfolio went to Resideo as a stand-alone company, and Honeywell licensed the Honeywell Home brand to Resideo under a long-term agreement. That is why the brand still appears on the box while the company behind it is Resideo.

The practical consequence for anyone ordering parts: the model numbering carried over. Across the 606 Resideo parts we stock, the numbers follow the same historic Honeywell series they always did. An L8148E aquastat relay is still listed as an L8148E. A VR8345Q universal gas valve is still a VR8345Q. A ZD zone damper is still a ZD.

So the number in your old manual is almost always the number to order. You are not looking for a replacement part — you are looking for the same part with a different company name on the label.

Part number series index

Every Honeywell control series we carry, what it covers, and where it sits in the catalog.

Hydronic controls

Series What it is Example Where to find it
L Aquastat relays, limit controls L8148E1299 Aquastats and wells, fan and limit controllers
V 2-way zone valves, radiator valves V8043, V110D1016 2-way zone valves, thermostatic radiator valves
VC / VU Zone valve powerheads, fan coil valves VC8110ZZ32, VU844A1060 Replacement heads, fan coil zone valves
VCZZ Zone valve internal parts VCZZ7100 Zone valve parts
AM Thermostatic mixing valves AM100-002RP Mixing valves
DS / K Pressure reducing and fill valves DS06-105-SUT-LF Pressure reducing valves
PV / HS Air separators, hydraulic separators PV150P Air separators
TK Boiler trim kits TK30PV125SNK Boiler trim kits

Gas and ignition

Series What it is Example Where to find it
VR / SV Gas valves and gas controls VR8345Q4563, SV9641M4510 Gas valves
Q Pilot assemblies, thermocouples, ignition components Q4100C9068 Gas ignition components, thermocouples
S Ignition control modules S8910U3000 Gas ignition components
R Oil burner primary controls R8184G Oil burner controls

Zoning and switching

Series What it is Example Where to find it
ZD / ARD Rectangular and round zone dampers ZD8X20TZ, ARD7TZ Zone dampers
HZ Forced air zone panels HZ322 Forced air zone panels
HPZC / HPSR Zone valve controllers, switching relays HPZC106 Switching relays
R Fan centers, general purpose relays R8285A1048, R841D1036 Relays
AT Low-voltage transformers AT150F1022 Transformers
DP Definite purpose contactors DP3040C5001 Contactors

Thermostats and air

Series What it is Example Where to find it
TH Current thermostat line — T3, T4, T6 Pro and PRO series TH3110U2008, TH114-A-240D-B Thermostats
T / TL Legacy and line-voltage thermostats T812A1010 Non-programmable, line voltage
THP / C RedLINK accessories, sensors C7735A1000 Thermostat accessories
F / FC Media air cleaners and filters FC40R1029 Air cleaners and filters
HC / HM Humidifier pads and units HC26E1004 Humidifiers and dehumidifiers
VWS Water leak detection and shutoff VWS1000 Leak detection valves

Where the number genuinely does change

The rebrand did not renumber parts, but parts do get superseded over time, and that happens independently of what is written on the box. Two cases to watch:

Gas valves and ignition assemblies. These are matched to the appliance and often to a serial range within a single model, because the manufacturer revises the component without changing the appliance name. Order from the data plate on the equipment, not from the model name of the furnace or boiler.

Discontinued controls with a functional replacement. Where an older control is no longer produced, the replacement usually differs in more than the number — terminal layout, switch action or voltage may change. Confirm the specification rather than assuming a drop-in.

Two checks before you order

Voltage. Low-voltage 24V controls drive a system through a transformer and relay and cover most gas and hydronic equipment. Line voltage switches 120V or 240V directly and belongs to electric baseboard and radiant. Connecting one to the wrong system is a fire risk, not a malfunction.

Aquastat and well together. An aquastat has to be paired with the correct immersion well, seated to the bottom with conducting paste. Well length and bulb diameter have to match, or the control reads the air in the well and responds late.

The full range is in the Resideo collection — over 600 controls and parts in stock.