Watts LF007M2-QT-FZ 114 1-1/4" Lead Free Double Check Valve Backflow Preventer Assembly, Quarter Turn Shutoff, Freeze Sensor
- Item #
- WATT-T063233
- Mfr. part #
- LF007M2-QT-FZ 114
Need a larger quantity or a job quote? Request a quote →
- TypeDouble Check Valve Assembly
- Connection size1-1/4"
- ConnectionFemale Threaded
- MaterialLead Free Bronze
- BypassNo
| Brand | Watts |
| Manufacturer part # | LF007M2-QT-FZ 114 |
| Bypass | No |
| Connection Size | 1-1/4" |
| Connection Type | Female Threaded |
| Material | Lead Free Bronze |
| Test Status | Testable |
| Type | Double Check Valve Assembly |
Watts LF007M2-QT-FZ 114 is a 1-1/4" lead free double check valve backflow preventer assembly with quarter turn shutoffs, single top entry and a freeze sensor.
The manufacturer says a double check assembly is designed to prevent polluted water from flowing back into the potable supply due to backsiphonage or backpressure. It has a lead free body, NPT end connections, quarter turn ball valve shutoffs, top mounted test cocks and replaceable check discs and seats.
The compact modular design uses a single access cover for in-line repairs. Backflow assemblies are regulated, so check local water authority requirements and testing rules before ordering. The instruction manual and specification sheet are linked below.
Specifications
- Brand: Watts
- Manufacturer Part #: LF007M2-QT-FZ 114
- Connection Size: 1-1/4"
- Connection Type: Female Threaded
- Material: Lead Free Bronze
- Bypass: No
- Test Status: Testable
- Type: Double Check Valve Assembly
- Category: Backflow Preventers
Documents
- Instruction Manual (PDF)
- Specification Sheet (PDF)
See also: all Watts products.
Questions about fit or compatibility? Ask our team. We usually reply within one business day.
More in Backflow Preventers
Zurn Wilkins RK4-375CK1 #1 Check Assembly Repair Kit for 2-1/2" - 4" 375A, 4" 375DA, 475DA and 475DAV
Resideo 904182 Check Valve Insert, NK300S-100
Resideo 903733 Complete Cartridge Insert for BA/NK, 1/2–1 in
Caleffi 574006A 574 Series Reduced Pressure Zone (RPZ) Backflow Preventer, 1" NPT Threaded, ASSE 1013, Low Lead
Caleffi 573503A 573 Series Dual Check Backflow Preventer with Atmospheric Vent 3/4" NPT, ASSE 1012
Caleffi 574050A 574 Series Reduced Pressure Zone (RPZ) Backflow Preventer, 3/4" NPT Threaded, ASSE 1013, Low Lead
Caleffi 573403A 573 Series Dual Check Backflow Preventer with Atmospheric Vent 1/2" NPT, ASSE 1012
Caleffi 574004A 574 Series Reduced Pressure Zone (RPZ) Backflow Preventer, 1/2" NPT Threaded, ASSE 1013, Low Lead
Zurn Wilkins 2-375XL 2" 375XL Reduced Pressure Principle Backflow Preventer
Watts 0063235 2" Lead Free Double Check Valve Backflow Preventer Assembly, Quarter Turn Shutoff, Single Top Entry
Caleffi 574161A AutoFill 1" FNPT x 1" NPT Male Union Fill Valve with Testable Backflow Preventer
Resideo BP900/U Backflow Preventer with Intermediate Atmospheric Vent, 1/2 in NPT