Honeywell Home TH114-A-240D-B/U Line Volt Manual Thermostat for Electric Heat

Honeywell Home TH114-A-240D-B/U Line Volt Manual Thermostat for Electric Heat

Item #
HONE-TH114-A-240D-B/U
Mfr. part #
TH114-A-240D-B/U
UPC
775264924781
Key specifications
  • ColorWhite
  • MountingVertical
  • Supply Voltage240 Vac
  • Frequency50 Hz; 60 Hz
  • Ambient Temperatur32 F to 122 F
View all specifications
$102.74
Each
In stock – 9 available
Estimated delivery: –

Usually ships in 1–2 business days.

  • Free shipping on orders $99+
  • 30-day returns on unused items. Details
  • Secure checkout
BrandHoneywell Home
Manufacturer part #TH114-A-240D-B/U
Supply Voltage240 Vac
Frequency50 Hz; 60 Hz
Electrical Connections6 in. (150 mm) tinned copper lead wires
Electrical RatingsMax. 3600 W @ 240 V, 15 A resistive
Ambient Temperature32 F to 122 F
MountingVertical
ApplicationBaseboard heater; Radiant ceiling; Convector or Fan-forced Heater; Electric Heating
Used WithAube CT240/CT241 Telephone Controller
Dimensions4.9 in. X 2.8 in. X 0.9 in.
ULApproved
CSAApproved; Compliant to CAN/CSA-C828-06
Switch Positions (System)AF (ambient + floor)/F (floor only); °C/°F (switch MUST be set to AF for this thermostat to be operational)
Power MethodHardwired
ColorWhite
Sensor ElementThermistor
Accuracy (F)0.9 F
Differential Temperature (F)1 F
Switching ActionDPST
Switch TypeEpoxy-soundproofed relay
Setting Temperature Range (F)40 F to 86 F
Cycles per Hour4
UPC775264924781

The TH114-A-240D-B is a line-voltage thermostat from Honeywell Home for electric resistance heat — baseboard, convectors, radiant ceiling or panel heaters, wired for 240 V.

Line voltage is the distinction that matters here. A low-voltage thermostat switches a 24 V control circuit and lets a furnace or boiler do the work; a line-voltage thermostat carries the full heater current itself. They are not interchangeable, and a low-voltage stat wired to a baseboard circuit fails immediately.

This is a double-pole thermostat: it breaks both legs of the supply, so the heater is fully de-energized when the thermostat is satisfied or turned off. Double-pole is what most jurisdictions require on 240 V baseboard, and it is what makes the heater safe to work on with the thermostat off.

This is a manual thermostat: one setpoint, held until someone changes it. In a room that is occupied on no particular schedule — a workshop, a spare room, a rental — a manual stat is the one that actually gets used, because no one has to reprogram it after a power cut.

Rated temperature accuracy is 0.9 °F. On electric heat that number is felt directly: a stat with a wide swing runs the room warm to avoid running it cold, and the extra degree is paid for every hour.

Match the voltage and the pole configuration to the heater circuit, and check the amperage of the heater against the rating of the thermostat. A thermostat sized below the load is the most common cause of a line-voltage stat failing in its first season.

  • Brand: Honeywell Home
  • Manufacturer Part #: TH114-A-240D-B/U
  • Type: Line-voltage thermostat
  • Voltage: 240 V
  • Poles: Double-pole
  • Control: Manual
  • Accuracy: 0.9 °F
  • UPC: 775264924781
  • Category: Line Voltage Thermostats